Shaping ability of thermomechanically treated files in simulated S-shaped root canals

Abstract

Aim: the aim of this study was to investigate the shaping ability of thermomechanically treated files manufactured by twisting(Twisted files)and compare it to conventional rotary system (K3, Sybron Endo, Orange, CA) in S-shaped canals, including formation of ledges, zipping, elbow, outer widening, danger zone, perforation and file deformation. Materials & Methods: Forty S-Shaped canals in resin blocks were randomly divided into 2 groups of 20 each. Pre-instrumentation images of the canals were taken via a digital camera and superimposed on images taken after preparation with TF and K3 systems to apical size of 25/06 and 30/06. Canal aberrations were measured from the superimposed image at five levels using AutoCAD system. Fisher exact test and Mann Whitney test were used for analysis of the data. Results: the incidence of zipping, elbow and apical transportation was significantly lower in the TF group (P = 0.04). Generally the incidence of aberration increased when the apical size increased to 30/0.06 regardless of the file system. Significant file deformation was evident in the TF after single use (P ? 0.001). Conclusion: Under the conditions of this study, TF manufactured by new technique performed better than K3 systems when used up to size 25/06 in simulated S-shaped canals. Clinical significance: The flexibility of thermomechanically treated files is beneficial in canals with multiple curvatures; however, attention should be paid to the instrument taper and final apical size of the preparation.

Share and Cite:

Taha, N. , Maghaireh, G. , Sadek, D. , Bagheri, R. and Al-Omari, M. (2013) Shaping ability of thermomechanically treated files in simulated S-shaped root canals. Open Journal of Stomatology, 3, 386-391. doi: 10.4236/ojst.2013.37065.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Schilder, H. (1974) Cleaning and shaping the root canal. Dental Clinics of North America, 18, 269-296.
[2] Wu, M.K., Fan, B. and Wesselink, P.R. (2000) Leakage along apical root fillings in curved root canals. Part I: Effects of apical transportation on seal of root fillings. Journal of Endodontics, 26, 210-216.
http://dx.doi.org/10.1097/00004770-200004000-00003
[3] Tan, B.T. and Messer, H.H. (2002) The quality of apical canal preparation using hand and rotary instruments with specific criteria for enlargement based on initial apical file size. Journal of Endodontics, 28, 658-664.
http://dx.doi.org/10.1097/00004770-200209000-00008
[4] Schafer, E, Schulz-Bongert, U. and Tulus, G. (2004) Comparison of hand stainless steel and nickel titanium rotary instrumentation: A clinical study. Journal of Endodontics, 30, 432-435.
http://dx.doi.org/10.1097/00004770-200406000-00014
[5] Glossen, C.R., Haller, R.H., Dove, S.B. and del Rio, C.E. (1995) A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. Journal of Endodontics, 21,146-151.
http://dx.doi.org/10.1016/S0099-2399(06)80441-3
[6] Schafer, E. and Schlingemann, R. (2003) Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile. Part 2. Cleaning effectiveness and shaping ability in severely served root canals of extracted teeth. International Endodontic Journal, 36, 208-217.
http://dx.doi.org/10.1046/j.1365-2591.2003.00644.x
[7] Gambarini, G., Grande, N.M., Plotino, G., Somma, F., Garala, M, De Luca, M., et al. (2008) Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing method. Journal of Endodontics, 34, 1003-1005.
http://dx.doi.org/10.1016/j.joen.2008.05.007
[8] Gergi, R., Rjeily, J.A., Sader, J. and Naaman, A. (2010) Comparison of canal transportation and centering ability of twisted files, Pathfile-ProTaper system, and stainless steel hand K-files by using computed tomography. Journal of Endodontics, 36, 904-907.
http://dx.doi.org/10.1016/j.joen.2009.12.038
[9] El Batouty, K.M. and Elmallah, W.E. (2011) Comparison of canal transportation and changes in canal curvature of two nickel-titanium rotary instruments. Journal of Endodontics, 37, 1290-1292.
http://dx.doi.org/10.1016/j.joen.2011.05.024
[10] Guttmaan, J.L. (1997) Problem solving in endodontics. 3rd Edition, Mosby-Year book Inc., Missouri, 116.
[11] Bonaccorso, A., Cantatore, G., Condorelli, G.G., Schafer, E. and Tripi, T.R. (2009) Shaping ability of four nickeltitanium rotary instruments in simulated S-shaped canals. Journal of Endodontics, 35, 883-886.
[12] Burroughs, J.R., Bergeron, B.E., Roberts, M.D., Hagan, J.L. and Himel, V.T. (2012) Shaping ability of three nickel-titanium endodontic file systems in simulated S-shaped root canals. Journal of Endodontics, 38, 1618-1621.
http://dx.doi.org/10.1016/j.joen.2012.09.011
[13] Bryant, S.T., Thompson, S.A., al-Omari, M.A. and Dummer, P.M. (1998) Shaping ability of ProFile rotary nickel-titanium instruments with ISO sized tips in simulated root canals: Part 2. International Endodontic Journal, 31, 282-289. http://dx.doi.org/10.1046/j.1365-2591.1998.00150.x
[14] Rangel, S, Cremonese, R., Bryant, S. and Dummer, P. (2005) Shaping ability of RaCe rotary nickel-titanium instruments in simulated root canals. Journal of Endodontics, 31, 460-463.
http://dx.doi.org/10.1097/01.don.0000148144.79173.aa
[15] Yoshimine, Y., Ono, M. and Akamine, A. (2005) The shaping effects of three nickel-titanium rotary instruments in simulated S-shaped canals. Journal of Endodontics, 31, 373-375.
http://dx.doi.org/10.1097/01.don.0000140568.40462.43
[16] Al-Omari, M.A., Dummer, P.M. and Newcombe, R.G. (1992) Comparison of six files to prepare simulated root canals. International Endodontic Journal, 25, 57-66.
http://dx.doi.org/10.1111/j.1365-2591.1992.tb00738.x
[17] Shen, Y., Zhou, H.M., Zheng, Y.F., Peng, B. and Haapasalo, M. (2013) Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments. Journal of Endodontics, 39, 163-172.
http://dx.doi.org/10.1016/j.joen.2012.11.005
[18] Kim, H.C., Yum, J., Hur, B. and Cheung, G.S. (2009) Cyclic fatigue and fracture characteristics of ground and twisted nickel-titanium rotary files. Journal of Endodontics, 36, 147-152.
http://dx.doi.org/10.1016/j.joen.2009.09.037
[19] Ersev, H., Yilmaz, B., Ciftcioglu, E. and Ozkarsli, S.F. (2010) A comparison of the shaping effects of 5 nickeltitanium rotary instruments in simulated S-shaped canals. Oral Surgery Oral Medicine Oral Pathology Oral Radi ology and Endodontics, 109, e86-93.
http://dx.doi.org/10.1016/j.tripleo.2009.12.033
[20] Duran-Sindreu, F., Garcia, M., Olivieri, J.G., Mercade, M., Morello, S. and Roig, M. (2012) A comparison of apical transportation between FlexMaster and Twisted Files rotary instruments. Journal of Endodontics, 38, 993-995. http://dx.doi.org/10.1016/j.joen.2012.03.019
[21] Schafer, E., Dzepina, A. and Danesh, G. (2003) Bending properties of rotary nickel-titanium instruments. Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontics, 96, 757-763.
http://dx.doi.org/10.1016/S1079-2104(03)00358-5
[22] Card, S.J., Sigurdsson, A, Orstavik, D. and Trope, M. (2002) The effectiveness of increased apical enlargement in reducing intracanal bacteria. Journal of Endodontics, 28, 779-783.
http://dx.doi.org/10.1097/00004770-200211000-00008
[23] Hilfer, P.B., Bergeron, B.E., Mayerchak, M.J., Roberts, H.W. and Jeansonne B.G. (2010) Multiple autoclave cycle effects on cyclic fatigue of nickel-titanium rotary files produced by new manufacturing methods. Journal of Endodontics, 37, 72-74.
http://dx.doi.org/10.1016/j.joen.2010.09.011

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.