Teaching Ultrasound Imaging for Central Line Placement—A Resident’s Perspective

Abstract

The availability of ultrasound (US) devices has refined techniques for vascular access. The resident trainee’s ability to learn US techniques depends upon device availability, skills, and motivation of instructors. We hypothesized that hands-on teaching program of US techniques for vascular access would have a positive impact on the trainee’s perceptions. After IRB approval, PGY3 anesthesiology residents with limited prior experience in US-guided vascular access underwent close supervision by attending staff as they performed US-guided Internal Jugular Vein (IJV) central line placements. A total of 66 land mark (LM) and 75 US-guided IJV cannulation performed by 19 residents were supervised. Residents completing the study were more proactive with 68.4% agreeing to use US based techniques for an anticipated difficulty in accessing central lines. The graduating residents involved in the study all strongly agreed that US imaging for vascular access was within the scope of practice of all anesthesiologists, and that training guidelines be established and incorporated in their practice. Fifty eight percent of residents stated that their confidence and skill levels had significantly improved. Teaching US-guided techniques resulted in an increase employment of such techniques by graduating residents with no impediment attributed to knowledge deficits or inexperience. Residents were more proactive with using US for anticipated difficulty in IJV placement. A short neck, poor landmark, anticoagulation, morbid obesity favored US use by residents. Systematic teaching of US techniques is justified as it significantly improves the resident’s perceptions and confidence.

Share and Cite:

J. Mukherji, N. Ural, T. Sheikh and W. Jellish, "Teaching Ultrasound Imaging for Central Line Placement—A Resident’s Perspective," Open Journal of Anesthesiology, Vol. 3 No. 5, 2013, pp. 263-271. doi: 10.4236/ojanes.2013.35058.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] [1] A. G. Randolph, D. J. Cook, C. A. Gonzales and C. G. Pribble, “Ultrasound Guidance for Placement of Central Venous Catheters: A Meta-Analysis of the Literature,” Critical Care Medicine, Vol. 24, No. 12, 1996, pp. 2053-2058. doi:10.1097/00003246-199612000-00020
[2] D. Hind, N. Calvert, R. McWilliams, A. Davidson, S. Paisley, C. Beverley and S. Thomas, “Ultrasonic Locating Devices for Central Venous Cannulation: Meta-Analysis,” British Medical Journal, Vol. 327, No. 7411, 2003, p. 361. doi:10.1136/bmj.327.7411.361
[3] J. Leung, M. Duffy and A. Finckh, “Real-Time Ultrasonographically-Guided Internal Jugular Vein Catherization in the Emergency Department Increases Success Rates and Reduces Complications: A Randomized, Prospective Study,” Annals of Emergency Medicine, Vol. 48, No. 5, 2006, pp. 540-547. doi:10.1016/j.annemergmed.2006.01.011
[4] D. Feller-Kopman, “Ultrasound-Guided Internal Jugular Access A Proposed Standardized Approach and Implications for Training and Practice,” Chest, Vol. 132, No. 1, 2007, pp. 302-309. doi:10.1378/chest.06-2711
[5] S. Howard, “A Survey Measuring the Impact of NICE Guidance 49: The Use of Ultrasound Locating Devices for Placing Central Venous Catheters,” 2004, http://www.nice.org.uk/pdf/Final_CVC_placement_survey_report.pdf
[6] S. Ruesch, B. Walder and M. Tramer, “Complications of Central Venous Catheters: Internal Jugular Versus Subclavian Access: A Systematic Review,” Critical Care Medicine, Vol. 30, No. 2, 2002, pp. 454-460. doi:10.1097/00003246-200202000-00031
[7] M. Salman, M. Potter, M. Ethel, et al., “Recurrent Laryngeal Nerve Injury: A Complication of Central Venous Catheterization: A Case Report,” Angiology, Vol. 55, No. 3, 2004, pp. 345-346. doi:10.1177/000331970405500316
[8] M. Ohlgisser and M. Heifetz, “An Injury of the Stellate Ganglion Following Introduction of a Canula into the Inner Jugular Vein (Horner’s Syndrome),” Anaesthesist, Vol. 33, No. 7, 1984, pp. 320-321.
[9] S. T. Verghese, W. A. McGill, R. I. Patel, et al., “Comparison of Three Techniques for Internal Jugular Vein Cannulation in Infants,” Pediatric Anesthesia, Vol. 10, No. 5, 2000, pp. 505-511. doi:10.1046/j.1460-9592.2000.00554.x
[10] T. D. Girard and J. M. Schectman, “Ultrasound Guidance during Central Venous Catheterization: A Survey of Use By House Staff Physicians,” Journal of Critical Care, Vol. 20, No. 3, 2005, pp. 224-229. doi:10.1016/j.jcrc.2005.06.005
[11] P. Armstrong, R. Sutherland and D. Scott, “The Effect of Position and Different Maneuvers on Internal Jugular Vein Diameter Size,” Acta Anaesthesiologica Scandinavica, Vol. 38, 1994, pp. 229-231. doi:10.1111/j.1399-6576.1994.tb03879.x
[12] C. Sulek, N. Gravenstein, R. Blackshear, et al., “Head Rotation During Internal Jugular Vein Cannulation and the Risk of Caratid Artery Puncture,” Anesthesia & Analgesia, Vol. 82, No. 1, 1996, pp. 125-128.
[13] T. Maecken and T. Grau, “Ultrasound Imaging in Vascular Access,” Critical Care Medicine, Vol. 35, Suppl. 5, 2007, pp. S179-S185.
[14] M. Blaivas, L. Brannam and E. Fernandez, “Short-Axis Versus Long-Axis Approaches for Teaching UltrasoundGuided Vascular Access on a New Inanimate Model,” Academic Emergency Medicine, Vol. 10, No. 12, 2003, pp. 1307-1311. doi:10.1111/j.1553-2712.2003.tb00002.x
[15] C. D. Froehlich, M. R. Ridby, E. S. Rosenberg, R. Li, et al., “Ultrasound-Guided Central Venous Catheter Placement Decreases Complications and Decreases Placement Attempts Compared with the Landmark Technique in Patients in a Pediatric Intensive Care Unit,” Critical Care Medicine, Vol. 37, No. 3, 2009, pp. 1090-1096. doi:10.1097/CCM.0b013e31819b570e
[16] L. Oguzkurt, F. Tercan, G. Kara, D. Torun, O. Kizilkilic and T. Yildirim, “US-Guided Placement of Temporary Internal Jugular Vein Catheters: Immediate Technical Success and Complications in Normal and High-Risk Patients,” European Journal of Radiology, Vol. 55, No. 1, 2005, pp. 125-129.
[17] B. G. Denys, B. F. Uretsky and P. S. Reddy, “Ultrasound Assisted Cannulation of the Internal Jugular Vein: A Prospective Comparison to the External Landmarkguided Technique,” Circulation, Vol. 87, No. 5, 1993, pp. 1557-1562. doi:10.1161/01.CIR.87.5.1557
[18] D. L. Mallory, W. T. McGee, T. H Shawker, et al., “Ultrasound Guidance Improves the Success Rate of Internal Jugular Vein Cannulation: A Prospective, Randomized Trial,” Chest, Vol. 98, No. 1, 1990, pp. 157-160. doi:10.1378/chest.98.1.157
[19] C. A. Troianos, D. R. Jobes and N. Ellison, “Ultrasoundguided Cannulation of the Internal Jugular Vein: A Prospective, Randomized Study,” Anesthesia & Analgesia, Vol. 72, No. 6, 1991, pp. 823-826. doi:10.1213/00000539-199106000-00020
[20] M. J. Martin, F. A. Husain, M. Piesman, P. S. Mullenix, S. R. Steele, C. A. Andersen and G. N. Giacoppe, “Is Routine Ultrasound Guidance for Central Line Placement Beneficial? A Prospective Analysis,” Journal of Current Surgery, Vol. 61, No. 1, 2004, pp. 71-74. doi:10.1016/j.cursur.2003.07.010

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.