Signal Enhancements in Plasmon Assisted Fluorescence Ratiometric Imaging Optodes

Abstract

The objective of this study was to benchmark the different signal enhancements found in a recently exploited fluorescence ratiometric optode design used for nano-molar imaging of ammonium and ammonia. The sensing scheme of these optodes are based on a mediated transfer of the analyte together with a fluorescent dye in a two-phase system consisting of a gold nanoparticle (GNP) doped ether (organic phase), emulsified in a hydrogel (hydrous phase). The coextraction of the ion dye pair causes changes in fluorescence in relation to the analyte concentration. Performances of optodes with and without GNPs using the gradually improved instrumentation and signal processing were evaluated and normalized to be comparable. Signal to noise was enhanced due to signal processing based on ensemble averaging (1.7× - 3.2×), CCD sensitivity (2×), and plasmon assisted fluorescence (10× - 100×), which altogether with the ratiometric treatment of the fluorescence contributed to the great sensitivity for ammonium and ammonia. The study shows that GNP doped sensors are relatively more sensitive to matrix effects but if they are isolated by a protective layer they will dramatically increase in sensitivity. Proper isolation of the active chemical components from the matrix will make the sensor design one of the most powerful and versatile concepts for chemical imaging and single point detection in complex environments as the optodes likely can be constructed for most ions that have selective ionophores.

Share and Cite:

N. Strömberg, "Signal Enhancements in Plasmon Assisted Fluorescence Ratiometric Imaging Optodes," Optics and Photonics Journal, Vol. 3 No. 1, 2013, pp. 135-139. doi: 10.4236/opj.2013.31022.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] C. Krause, T. Werner, C. Huber, O. S. Wolfbeis and M. J. P. Leiner, “pH-Insensitive Ion Selective Optode: A Coex traction-Based Sensor for Potassium Ions,” Analytical Chemistry, Vol. 71, No. 8, 1999, pp. 1544-1548. doi:10.1021/ac981042x
[2] C. Huber, T. Werner, C. Krause, O. S. Wolfbeis and M. J. P. Leiner, “Overcoming the pH Dependency of Optical Sensors: A pH-Independent Chloride Sensor Based on Co-Extraction,” Analytica Chimica Acta, Vol. 398, No. 2-3, 1999, pp. 137-143. doi:10.1016/S0003-2670(99)00414-6
[3] C. Krause, T. Werner, C. Huber and O. S. Wolfbeis, “Emulsion-Based Fluorosensors for Potassium Featuring Improved Stability and Signal Change,” Analytical Chemistry, Vol. 71, No. 1999, pp. 5304-5308. doi:10.1021/ac9907383
[4] C. Krause, T. Werner and O. S. Wolfbeis, “Multilayer Potassium Sensor Based on Solid-State Coextraction,” Analytical Sciences, Vol. 14, No. 1, 1998, pp. 163-167. doi:10.2116/analsci.14.163
[5] N. Stromberg and S. Hulth, “Ammonium Selective Fluorosensor Based on the Principles of Coextraction,” Analytica Chimica Acta, Vol. 443, No. 2, 2001, pp. 215-225. doi:10.1016/S0003-2670(01)01221-1
[6] N. Stromberg and S. Hulth, “A Fluorescence Ratiometric Detection Scheme for Ammonium Ions Based on the Sol vent Sensitive Dye MC 540,” Sensors and Actuators B: Chemical, Vol. 90, No. 1-3, 2003, pp. 308-318. doi:10.1016/S0925-4005(03)00053-4
[7] N. Str?mberg and S. Hulth, “High-Precision Ratiometric Detection of NH4+ in Natural Waters,” Europtode VI, Manchester, 2002.
[8] N. Stromberg and S. Hulth, “Assessing an Imaging Ammonium Sensor Using Time Correlated Pixel-by-Pixel calibration,” Analytica Chimica Acta, Vol. 550, No. 1-2, 2005, pp. 61-68. doi:10.1016/j.aca.2005.06.074
[9] N. Stromberg and S. Hulth, “Time Correlated Pixel by-Pixel Calibration for Quantification and Signal Quality Control during Solute Imaging,” Sensors and Actua tors B: Chemical, Vol. 115, No. 1, 2006, pp. 263-269. doi:10.1016/j.snb.2005.09.012
[10] N. Stromberg, J. Engelbrektsson and S. Delin, “A High Throughput Optical System for Imaging Optodes,” Sensors and Actuators B: Chemical, Vol. 140, No. 2, 2009, pp. 418-425. doi:10.1016/j.snb.2009.05.011
[11] N. Stromberg, “Determination of Ammonium Turnover and Flow Patterns Close to Roots Using Imaging Opto des,” Environmental Science & Technology, Vol. 42, No. 5, 2008, pp. 1630-1637. doi:10.1021/es071400q
[12] S. Delin and N. Stromberg, “Imaging-Optode Measurements of Ammonium Distribution in Soil after Different Manure Amendments,” European Journal of Soil Science, Vol. 62, No. 2, 2011, pp. 295-304. doi:10.1111/j.1365-2389.2010.01326.x
[13] J. R. Lakowicz, K. Ray, M. Chowdhury, H. Szmacinski, Y. Fu, J. Zhang and K. Nowaczyk, “Plasmon-Controlled Fluorescence: A New Paradigm in Fluorescence Spectroscopy,” Analyst, Vol. 133, No. 10, 2008, pp. 1308-1346. doi:10.1039/b802918k
[14] A. Hakonen, “Plasmon Enhancement and Surface Wave Quenching for Phase Ratiometry in Coextraction-Based Fluorosensors,” Analytical Chemistry, Vol. 81, No. 11, 2009, pp. 4555-4559. doi:10.1021/ac8025866
[15] N. Str?mberg and A. Hakonen, “Plasmophore Sensitized Imaging of Ammonia Release from Biological Tissues Using Optodes,” Analytica Chimica Acta, Vol. 704, No. 1-2, 2011, pp. 139-145. doi:10.1016/j.aca.2011.08.019
[16] A. Hakonen and N. Stromberg, “Diffusion Consistent Calibrations for Improved Chemical Imaging Using Nanoparticle Enhanced Optical Sensors,” Analyst, Vol. 137, No. 2, 2012, pp. 315-321. doi:10.1039/c1an15528h
[17] D. A. Skoog, F. J. Holler and T. A. Nieman, “Principles of Instrumental Analysis,” In: F. Messina, Ed., Principles of Instrumental Analysis, Saunders Collage Publishing, Philadelphia, 1998, pp. 99-114.
[18] A. Hakonen and N. Stromberg, “Plasmonic Nanoparticle Interactions for High-Performance Imaging Fluorosensors,” Chemical Communications, Vol. 47, No. 12, 2011, pp. 3433-3435. doi:10.1039/c0cc04972g

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.