American Journal of Analytical Chemistry

Volume 2, Issue 8 (December 2011)

ISSN Print: 2156-8251   ISSN Online: 2156-8278

Google-based Impact Factor: 1.71  Citations  h5-index & Ranking

Evaluation of Response Surface Methodology in Dispersive Liquid-Liquid Microextraction for Lead Determination Using Ionic Liquids

HTML  Download Download as PDF (Size: 684KB)  PP. 892-901  
DOI: 10.4236/ajac.2011.28103    4,816 Downloads   8,754 Views  Citations

Affiliation(s)

.

ABSTRACT

This paper describes a dispersive liquid–liquid microextraction (DLLME) procedure using room temperature ionic liquids (RTILs) coupled with flame atomic absorption spectrometry detection with microsample intro-duction system capable of quantifying trace amounts of lead. In the proposed approach, ammonium pyr-rolidine dithiocarbamate (APDC) was used as a chelating agent and 1-hexyl-3-methylimmidazolium bis (trifluormethylsulfonyl)imid as an extraction solvent was dissolved in acetone as the disperser solvent. The binary solution was then rapidly injected by a syringe into the water sample containing Pb2+ complex. Some factors influencing the extraction efficiency of Pb2+ and its subsequent determination, including extraction and dispersive solvent type, pH of sample solution, concentration of the chelating agent and salt effect were inspected by a full factorial design to identify important parameters and their interactions. Next, a central composite design was applied to obtain the optimum points of the important parameters. Under the optimum conditions, the limit of detection (LOD) was 0.2 µg/L. The relative standard deviation (R.S.D) was 1.4% for 5 µg/L of Pb2+ (n = 7). The relative recovery of lead in seawater, blood, tomato and black tea samples was measured.

Share and Cite:

B. Majidi, F. Shemirani and R. Khani, "Evaluation of Response Surface Methodology in Dispersive Liquid-Liquid Microextraction for Lead Determination Using Ionic Liquids," American Journal of Analytical Chemistry, Vol. 2 No. 8, 2011, pp. 892-901. doi: 10.4236/ajac.2011.28103.

Cited by

[1] Ionic liquids in biological monitoring for exposure assessments
Journal of Molecular …, 2021
[2] Determination of As, Cu, and Pb in different sugar samples by Atomic Absorption Spectrometer with the help of Multivariate Analysis
2020
[3] Evaluation and mechanism of cationic/anionic dyes extraction from water by ionic liquids
Chemical Engineering Communications, 2018
[4] Determination of lead by atomic fluorescence spectrometry using an automated extraction/pre-concentration flow system
Journal of Analytical Atomic Spectrometry, 2015
[5] Ligandless surfactant mediated solid phase extraction combined with Fe3O4 nano-particle for the preconcentration and determination of cadmium and lead in water …
Ecotoxicology and Environmental Safety, 2014
[6] Ligandless surfactant mediated solid phase extraction combined with Fe< sub> 3 O< sub> 4 nano-particle for the preconcentration and determination of cadmium and lead in water and soil samples followed by flame atomic absorption spectrometry: Multivariate strategy
Ecotoxicology and environmental safety, Elsevier, 2014
[7] Liquid-phase microextraction techniques based on ionic liquids for preconcentration and determination of metals
TrAC Trends in Analytical Chemistry, Elsevier, 2014

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.