World Journal of Nuclear Science and Technology

Volume 1, Issue 3 (October 2011)

ISSN Print: 2161-6795   ISSN Online: 2161-6809

Google-based Impact Factor: 0.38  Citations  h5-index & Ranking

Direct Determination of Radionuclides in the Body Optimisation of Measurements Parameters and Results Analysis

HTML  Download Download as PDF (Size: 907KB)  PP. 87-110  
DOI: 10.4236/wjnst.2011.13013    7,061 Downloads   13,354 Views  Citations

Affiliation(s)

.

ABSTRACT

Whole body counting (WBC) benefits from new types of detectors and methodologies. It has found applications in areas such as in medicine, protection of workers and of population. The design of a WBC facility should be tailored to the type of application. Monte Carlo calculations help to improve the reliability of the calibration of a facility, particularly for non-standard measurements (child, etc.), help in optimizing shielding of counting rooms, preventing large systematic errors and lowering detection limits. In vivo counting may be used to evaluate the distribution of radionuclides in organs for metabolic studies with multiple detectors or with a scan of the body. Reduction of detection levels by background reduction is limited. Improved sensitivity can be obtained by adapting the detector type and size to the measured photon energy. The benefit of comparison exercises and training courses are demonstrated. Further improvements in accuracy can be expected from cooperative works with other techniques: indirect methods (urines and faeces) and passive detectors placed correctly on the body can in the case of high levels of contamination can be used to improve the burden assessment.

Share and Cite:

J. Genicot, T. Fonseca, G. Kramer and A. Wambersie, "Direct Determination of Radionuclides in the Body Optimisation of Measurements Parameters and Results Analysis," World Journal of Nuclear Science and Technology, Vol. 1 No. 3, 2011, pp. 87-110. doi: 10.4236/wjnst.2011.13013.

Cited by

[1] KOMPARASI HASIL PERHITUNGAN PAPARAN INTERNAL URANIUM DAN PLUTONIUM PADA SAMPEL BIOASSAY ANTARA METODE KONVENSIONAL DENGAN MENGGUNAKAN SOFTWARE IMBA
Prosiding Seminar Nasional APISORA, 2018
[2] Comparison of the results of calculation internal exposure of uranium and plutonium at bioassay sample between using conventional and IMBA software methods
2018
[3] Снижение неопределенности результатов измерений содержания 90Sr, 137Cs и 40K в теле человека на спектрометре СИЧ-9.1М
2017
[4] Applicability of pulse shape analysis methods in measurements of low energy gamma rays from human lungs
2015
[5] Simulation of in vivo monitors and voxel phantoms for establishing calibration factors
2015
[6] MaMP and FeMP: computational mesh phantoms applied for studying the variation of WBC efficiency using a NaI (Tl) detector
Journal of Radiological Protection, 2014
[7] Simulation of in-vivo Monitors and VOXEL Phantoms for Establishing Calibration Factors
2014

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.