World Journal of Engineering and Technology

Volume 5, Issue 4 (October 2017)

ISSN Print: 2331-4222   ISSN Online: 2331-4249

Google-based Impact Factor: 0.80  Citations  

Experimental Study on Electrostatically Actuated Micro-Gripper Based on Silica Process

HTML  XML Download Download as PDF (Size: 634KB)  PP. 126-133  
DOI: 10.4236/wjet.2017.54B014    961 Downloads   1,643 Views  

ABSTRACT

The characteristics of a kind of comb-drive electrostatic actuated micro-gripper are tested. The test platform using a microscope-CCD-computer, the state information of the micro-gripper obtained by data acquisition and image processing, voltage-displacement characteristic curve is obtained and the mathematical equation is established. The analysis of the characteristic equation has shown the consistency and rationality of the theoretical design and the experimental results. The main factors that cause the difference between the theoretical design and the actual test performance are analyzed, and the design method and experimental results is obtained for the micro-gripper in the field of micro-assembly.

Share and Cite:

Yang, P. , Li, Y. , Li, Y. and Li, Q. (2017) Experimental Study on Electrostatically Actuated Micro-Gripper Based on Silica Process. World Journal of Engineering and Technology, 5, 126-133. doi: 10.4236/wjet.2017.54B014.