Journal of Biomedical Science and Engineering

Volume 4, Issue 10 (October 2011)

ISSN Print: 1937-6871   ISSN Online: 1937-688X

Google-based Impact Factor: 0.66  Citations  h5-index & Ranking

Comparison of fatigue behaviour of eight different hip stems: a numerical and experimental study

HTML  Download Download as PDF (Size: 1122KB)  PP. 643-650  
DOI: 10.4236/jbise.2011.410080    7,429 Downloads   13,343 Views  Citations

Affiliation(s)

.

ABSTRACT

In this study, finite element analysis was used to investigate the fatigue behavior of eight different hip stems. All of the prostheses investigated in the analysis are already being used in Turkish orthopaedic surgery. All stems were compared with each other in terms of fatigue, deformation and safety factors. Primary analysis was applied on three of the stems, which were tested experimentally. It was observed that the simulation and the experimental results are in good agreement with each other. After determining the reliability of the numerical method, the analysis was applied on all other stems. To obtain a more realistic simulation, boundary conditions were applied according to standards specified in the ISO 7206-4 standard. Three different types of materials were selected during analysis. These materials were Ti-6Al-4V, cobalt chrome alloy and 316L. Minimum fatigue cycles, critical fatigue areas, stresses and safety factor values have been identified. The results obtained from the finite element analysis showed that all stems were safe enough in terms of fatigue life. As a result of fatigue analysis, all stems have been found to be successful, but some of them were found to be better than the others in terms of safety factor. The current study has also demonstrated that analysing hip stems with the finite element method (FEM) can be applied with confidence to support standard fatigue testing and used as an alternative. Further studies can expand the simulations to the clinical relevance due to complex physical relevance.

Share and Cite:

Pekedis, M. and Yildiz, H. (2011) Comparison of fatigue behaviour of eight different hip stems: a numerical and experimental study. Journal of Biomedical Science and Engineering, 4, 643-650. doi: 10.4236/jbise.2011.410080.

Cited by

[1] Mechanical Performance of Artificial Hip Stems Manufactured by Hot Forging and Selective Laser Melting Using Biocompatible Ti-15Zr-4Nb Alloy
2021
[2] A finite element study of fatigue load effects on total hip joint prosthesis
2021
[3] Prediction of strength and durability of the femoral components of the Orten endoprosthesis basic system using the finite element method
Modern Science-Moderni …, 2020
[4] Risk analysis of additively manufactured bespoke medical implants through probabilistic numerical analysis
Swansea, Wales, UK: National Library Wales, 2020
[5] Biomechanical analysis to probe role of bone condition and bodyweight in stiffness customization of femoral stem for improved periprosthetic 2 …
2020
[6] Fatigue Life Estimation of 2 (3HUS+ S) Parallel Manipulator for Simulation of Hip Joint Motion
2020
[7] Biomechanical Analysis to Probe Role of Bone Condition and Subject Weight in Stiffness Customization of Femoral Stem for Improved Periprosthetic Biomechanical …
2020
[8] On the design and properties of porous femoral stems with adjustable stiffness gradient
2020
[9] Simulation of Hip Implant with respect to the Clearance between the Bone and Endoprosthesis: A Case Study
2020
[10] Biomechanical Analysis to Probe Role of Bone Condition and Bodyweight in Stiffness Customization of Femoral Stem for Improved Periprosthetic Biomechanical …
2020
[11] Influência dos parâmetros de usinagem na integridade superficial da liga biomédica de CoCr ASTM F75
2019
[12] Hip stem fatigue:: The implications of increasing patient mass
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2018
[13] Finite element analysis of newly introduced plates for mandibular condyle neck fracture treatment by open reduction and rigid fixation
2017
[14] Finite Element Analysis of Screw-Tightening Torque Applied to Custom and Conventional Abutment
Global Journal of Health Science, 2017
[15] Finite Element Method Application for Stress Distribution Analysis on Hip Stem Prosthesis Model for Walking and Climbing Stair
2017
[16] 人工髋关节股骨柄专用型疲劳测试装置研制
机械工程学报, 2016
[17] Fatigue Life Estimation of Artificial Hip Joint Model Using Finite Element Method
Materials Today: Proceedings, 2015
[18] ANALYSIS OF ARTIFICIAL HIP JOINT USING FINITE ELEMENT METHOD
WASET, 2015
[19] Analisis Hubungan Dimensi Stem dan Ballhead Terhadap Faktor Keamanan Fatik Hip Stem Prosthesis dengan Menggunakan Metode Elemen Hingga
2015
[20] Strength Evaluation of Bone Implant Strength Evaluation of Bone Implant
NT Manjare, SN Khan, AV Naik - ijreat.org, 2014
[21] Bone Mineral Density and Fracture Risk Assessment for Patients Undergoing Total Hip Replacement
2014
[22] A fatigue assessment technique for modular and pre-stressed orthopaedic implants
Medical engineering & physics, 2014
[23] A FATIGUE ASSESSMENT TECHNIQUE FOR MODULAR AND PRE-STRESSED 10 ORTHOPAEDIC IMPLANTS 11
Medical Engineering & Physics, 2014
[24] Femur protezinin sonlu elemanlar metodu ile nümerik analizi/Numerical analysis of the femur prosthesis by finite element method
2012

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.