ABSTRACT

The behavior of the 2006 ten Tusscher-Panfilov model of human ventricular myocytes under the impact of periodic excitation impulses was studied in the BeatBox simulation environment. The cardiomyocyte model has a limited susceptibility to an forced higher frequency excitation rhythm. A high-frequency excitation rhythm can be forced by gradually increasing the frequency of excitation impulses. The mechanism of defibrillation pulse impact consists of presumably prolonging the refractoriness of cardiomyocytes which undermines their susceptibility for a long time to a forced high-frequency rhythm of fibrillation, as a result for which they hinder the propagation of a fibrillation wave. This is the only mechanism of defibrillation that was identified during the simulation. The threshold energy of a depolarizing defibrillation pulse prolonging the refractoriness of the cardio-myocyte varies depending on a delay relative to the excitation impulse (the excitation cycle phase) in a wide range (the maximum value exceeds the minimum by several thousand times). The results show differences in the mechanisms of impact on a cardiomyocyte between an excitation impulse and a monophasic defibrillation pulse.

Share and Cite:

Gorbunov, B. (2017) Study of the Impact of Rectangular Current Pulses on the Ten Tusscher-Panfilov Model of Human Ventricular Myocyte. Journal of Biomedical Science and Engineering, 10, 355-366. doi: 10.4236/jbise.2017.107027.

Cited by

[1] Evaluation of the Effect of Chopping Modulation of a Defibrillation Pulse on Its Energy Efficiency Based on the Hypothesis of Guaranteed Defibrillation.
Biomedical Engineering, 2021
[2] Оценка влияния импульсной модуляции дефибрилляционного импульса на его энергетическую эффективность на основе гипотезы гарантированной …
Медицинская техника, 2021
[3] Сравнение энергетической эффективности дефибрилляционных импульсов на базе гипотезы гарантированной дефибрилляции
Ural Radio Engineering …, 2021
[4] Области эффективности полусинусоидальных монополярного и биполярного деполяризующих дефибрилляционных импульсов на диаграмме энергия/фаза …
Ural Radio Engineering …, 2021
[5] Области эффективности полусинусоидальных монополярного дефибрилляционных импульсов на диаграмме энергия/фаза цикла фибрилляции и …
URAL RADIO …, 2021
[6] The dependence of the fibrillation cycle fraction on which the defibrillation pulse is effective on the pulse energy
2020
[7] Guaranteed defibrillation on a cardiomyocyte model
2020
[8] Evaluation of the Influence of the Rise and Fall Times of a Monophasic Trapezoidal Defibrillation Pulse on Its Energy Efficiency Using the ten Tusscher–Panfilov …
2020
[9] Оценка влияния длительности фронта и среза дефибрилляционного монополярного трапецеидального импульса на его энергетическую …
2020
[10] Evaluation of the effect of chopping modulation of a defibrillation pulse on its energy efficiency based on the hypothesis of guaranteed defibrillation
2020
[11] The Effect of a Hyperpolarization Pulse on a Model of Cardiomyocyte under Fibrillation Conditions
2019
[12] Реакция модели кардиомиоцита, находящегося под воздействием фибрилляции, на гиперполяризующий импульс
2019
[13] The Effect of a Hyperpolarization Pulse on a Model of Cardiomyocyte under Fibrillation Conditions.
Biomedical Engineering, 2019
[14] Proceedings of the 11th International Conference on Bioelectromagnetism: 23-25 May 2018, Aachen, Germany
11. International …, 2018
[15] Реакция модели кардиомиоцита, находящейся под воздействием фибрилляции, на воздействие гиперполяризующего импульса
2018
[16] Areas of Effectiveness of Defibrillating Pulse in the Energy/Phase Diagram for the Fibrillation Cycle on the Cardiomyocyte Model
International Journal of Bioelectromagnetism, 2018
[17] Области эффективности импульса дефибрилляции на диаграмме энергии/фазы цикла фибрилляции для модели кардиомиоцита
2017

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.