American Journal of Analytical Chemistry

Volume 2, Issue 6 (October 2011)

ISSN Print: 2156-8251   ISSN Online: 2156-8278

Google-based Impact Factor: 1.71  Citations  h5-index & Ranking

Single Drop Microextraction of Biphenyl and Biphenyl Oxide in Aqueous Samples by Gas Chromatography-Flame Ionization Detection

HTML  Download Download as PDF (Size: 202KB)  PP. 689-696  
DOI: 10.4236/ajac.2011.26079    4,341 Downloads   8,171 Views  Citations

Affiliation(s)

.

ABSTRACT

In this work, biphenyl and biphenyl oxide were extracted by direct single drop microextraction (di- rect-SDME) and analyzed by gas chromatography flame ionization detection. The extraction occurred by suspending a 7 µL drop of toluene (as extracting solvent) containing acetonaphton (as internal standard) from the tip of a microsyringe in direct-SDME, respectively. The effect of different parameters such as nature of extraction solvent, microdrop and sample temperatures, stirring rate, microdrop and sample volumes, ionic strength and extracting time on the extraction efficiency of the analytes were investigated and optimized. Under optimized conditions the detection limits (S/N = 3) of the biphenyl and biphenyl oxide were 1.80 ± 0.03 and 1.10 ± 0.02 µg?mL–1, respectively. Good linearity was obtained for both analytes using extraction techniques with the correlation coefficients at least 0.997 and the relative standard deviations (R.S.D.) were in the range of 1% - 3%. The percent recoveries of the analytes from spiked water samples were near to 100%

Share and Cite:

M. Sarkhosh, A. Mehdinia, A. Jabbari and Y. Yamini, "Single Drop Microextraction of Biphenyl and Biphenyl Oxide in Aqueous Samples by Gas Chromatography-Flame Ionization Detection," American Journal of Analytical Chemistry, Vol. 2 No. 6, 2011, pp. 689-696. doi: 10.4236/ajac.2011.26079.

Cited by

[1] Development and comparative analysis of single-drop and solid-phase microextraction techniques in the residual determination of 2-phenoxyethanol in fish
Food Chemistry, 2019
[2] Development of magnetic solid-phase extraction coupled with dispersive liquid–liquid microextraction method for the simultaneous determination of biphenyl …
2019
[3] Headspace single‐drop microextraction with in‐drop derivatization followed by reversed‐phase HPLC analysis to determine residual acetaldehyde in polyethylene …
Separation Science Plus, 2018
[4] Development of magnetic solid-phase extraction coupled with dispersive liquid–liquid microextraction method for the simultaneous determination of biphenyl and …
2018
[5] Extraction and determination of biphenyl and biphenyl oxide in water samples by using ultrasound-assisted emulsification microextraction-gas chromatography-flame …
2012
[6] Extraction and determination of biphenyl and biphenyl oxide in water samples by using ultrasound-assisted emulsification microextraction-gas chromatography-flame ionization detection
Analytical Methods?, 2012
[7] DETERMINAÇÃO DE BROMOFENÓIS SIMPLES EM PEIXES POR MICROEXTRAÇÃO COM GOTA ÚNICA E CG-EM
2012

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.