Open Journal of Anesthesiology

Volume 7, Issue 4 (April 2017)

ISSN Print: 2164-5531   ISSN Online: 2164-5558

Google-based Impact Factor: 0.23  Citations  

Intraoperative Auditory Evoked Potential Monitoring for Anaesthesia Depth and Utilization of Inhaled Isoflurane

HTML  XML Download Download as PDF (Size: 400KB)  PP. 109-119  
DOI: 10.4236/ojanes.2017.74011    1,387 Downloads   2,794 Views  Citations

ABSTRACT

Background: Hypnosis monitoring has been shown to reduce the incidence of awareness. A-line ARX-IndexTM (AAI) derived from auditory evoked potentials (AEP) represents as a numerical variable depth of anaesthesia. Objectives: To study the efficacy of AEP as an indicator of anaesthetic depth and monitor intraoperative awareness in neurosurgical patients by using the AAI scale. Design: Prospective cohort study is used. Setting: The study is in Neurosurgical centre of Tertiary care hospital. Participants: Neurosurgical patients requiring general anaesthesia with duration of surgery between 90 - 150 minutes were enrolled for the study. Intervention: Patients in Group 1 (control) were monitored by conventional methods. Patients in Group 2 (study) underwent intraoperative monitoring by using the AEP monitor. Primary outcome: To study the efficacy of AEP monitoring and AAI index for monitoring the depth of anaesthesia and reducing the incidence of awareness. Results: There was no significant difference in the intraoperative haemodynamic responses measured between the two study groups (p > 0.5). There was no significant difference in the identification of intraoperative awareness by using conventional parameters between the two groups (p > 0.5). There was also a significantly faster time to recovery for patients in Group 2 (p < 0.05). Conclusion: Hypnosis monitoring using AEP monitor/AAI in neurosurgical patients under general anaesthesia did not show any significant difference in haemodynamic response and intraoperative awareness but had significant lower consumption of volatile anaesthetic with cost sparing effect and a faster recovery time as compared to conventional monitoring.

Share and Cite:

Tewari, K. and Murthy, T. (2017) Intraoperative Auditory Evoked Potential Monitoring for Anaesthesia Depth and Utilization of Inhaled Isoflurane. Open Journal of Anesthesiology, 7, 109-119. doi: 10.4236/ojanes.2017.74011.

Cited by

[1] Physiologic Monitoring: Technological Advances Improving Patient Safety
Catastrophic Perioperative Complications and Management, 2019

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.