Open Journal of Obstetrics and Gynecology

Volume 7, Issue 3 (March 2017)

ISSN Print: 2160-8792   ISSN Online: 2160-8806

Google-based Impact Factor: 0.37  Citations  h5-index & Ranking

Automatic Detection and Measurement of Fetal Biparietal Diameter and Femur Length —Feasibility on a Portable Ultrasound Device

HTML  XML Download Download as PDF (Size: 1203KB)  PP. 334-350  
DOI: 10.4236/ojog.2017.73035    1,940 Downloads   4,548 Views  Citations

ABSTRACT

An automatic method able to recognize a presented section through the biparietal plane of the fetal head and a section through the fetal femur in ultrasound images is developed. Once the correct anatomical section for measurement is identified by the machine, the placement of the measurement calipers is automatically determined by fitting an active contour model to the structure of interest. The fetal biparietal diameter (BPD) and femur length (FL) are then measured automatically. The validation data set contained 167 and 197 B-mode images for BPD and FL measurements, respectively. The images were acquired using 4 different ultrasound scanners, which resulted in varied image quality and gain settings. The mean gestational age (GA) of the fetuses was 19.4 weeks, range 16 to 41 weeks. A measurement success rate of 90% was achieved for both BPD and FL. The correlation coefficients between the manual and automatic measurements were 0.995 (BPD) and 0.967 (FL), mean errors were 0.5 mm (BPD) and -1.7 mm (FL) and error range with 95% confidence interval (CI) were 3.8 - 4.8 mm (BPD) and 11.4 - 8.1 mm (FL). The automatic measurement results were consistent in both high and low gain settings. The intraclass correlation coefficients between manual and automatic measurements were 0.995 (95% CI; 0.981 - 0.999) for BPD in high gain, 1.0 (95% CI; 0.998 - 1.0) for BPD in low gain, 0.998 (95% CI; 0.991 - 0.999) for FL in high gain and 0.999 (95% CI; 0.996 - 1.0) for FL in low gain settings. The method was implemented on a prototype, portable ultrasound machine designed to be used in low- and middle-income countries (LMIC). The overall performance of the method supports our hypothesis that automated methods can be used and are beneficial in a clinical setting.

Share and Cite:

Khan, N. , Tegnander, E. , Dreier, J. , Eik-Nes, S. , Torp, H. and Kiss, G. (2017) Automatic Detection and Measurement of Fetal Biparietal Diameter and Femur Length —Feasibility on a Portable Ultrasound Device. Open Journal of Obstetrics and Gynecology, 7, 334-350. doi: 10.4236/ojog.2017.73035.

Cited by

[1] BiometryNet: Landmark-based Fetal Biometry Estimation from Standard Ultrasound Planes
… Image Computing and …, 2022
[2] Automatic linear measurements of the fetal brain on MRI with deep neural networks
2021
[3] AutoFB: Automating Fetal Biometry Estimation from Standard Ultrasound Planes
2021
[4] Fetal brain MRI measurements using a deep learning landmark network with reliability estimation
Sira… - Uncertainty for Safe …, 2021
[5] Automatic Measurements of Fetal Lateral Ventricles in 2D Ultrasound Images Using Deep Learning
2020
[6] Feature Selection in Fetal Biometrics for Abnormality Detection in Ultrasound Images
Nature Inspired Optimization Techniques for Image Processing Applications, 2019
[7] Automatic femur length measurement for fetal ultrasound image using localizing region-based active contour method
2019
[8] Fully automatic segmentation and measurement of the fetal femur
2018
[9] Feature Selection in Fetal Biometrics for Abnormality Detection
2018
[10] Automatic Measurement of Fetal Abdominal Biometric Parameters—Feasibility on a Portable Ultrasound Device
2017

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.