Engineering

Volume 7, Issue 10 (October 2015)

ISSN Print: 1947-3931   ISSN Online: 1947-394X

Google-based Impact Factor: 0.66  Citations  

Performance of a Large-Scale Medical Waste Incinerator in a Referral Hospital

HTML  XML Download Download as PDF (Size: 2595KB)  PP. 676-690  
DOI: 10.4236/eng.2015.710059    5,743 Downloads   8,164 Views  Citations

ABSTRACT

The aim of the study was to analyze the performance of large scale incinerator installed in a referral hospital. The study involved weighing and loading infectious waste of different composition (sharps and other waste), recording temperatures in the primary and secondary chamber with time, fuel used and collecting and weighing the bottom ash for 65 days. The analysis shows that the incinerator on average uses 362 L/day (45 L/h) to incinerate 945 kg of medical waste (40.8 kg/day of sharps waste and 904 kg/day of other waste), generating 51.2 kg of ash daily. The observed fuel consumption rate was too high necessitating corrective action. The average weight reduction was 94.6%. The study shows that the average sharps waste composition for medical waste incinerated was 4.3% and other waste was 95.7%. The incinerator capacity ranged between 100 and 130 kg/h. The fuel effectiveness ranged between 2.0 and 3.0 liters of diesel per kg of waste incinerated. The fuel effectiveness increased linearly with total waste incinerated and incinerator capacity, respectively, depending on the fuel consumption rate.

Share and Cite:

Matee, V. and Manyele, S. (2015) Performance of a Large-Scale Medical Waste Incinerator in a Referral Hospital. Engineering, 7, 676-690. doi: 10.4236/eng.2015.710059.

Cited by

[1] Comprehensive review on medical waste incineration
… Journal of Global …, 2022
[2] ОБРАЩЕНИЕ С МЕДИЦИНСКИМИ ОТХОДАМИ В УСЛОВИЯХ СОВРЕМЕННОГО ЗДРАВООХРАНЕНИЯ-ПРОБЛЕМЫ И ПУТИ РЕШЕНИЯ
Кубанский научный …, 2022
[3] Thermal energy evaluation of the incinerator medical waste
GEOMATE Journal, 2021
[4] Performance and Simulations of Small-Scale Solid Waste Incinerators at Njokerio, Ng'ondu and Green Valley Areas in Njoro, Kenya
2021
[5] Assessment of Levels of Pollutants in Ashes, and Flue Gases Emanating from Medical Waste Incinerators in Selected Hospitals in Tanzania.
2021
[6] Assessment of the heavy metal-levels in the incinerators bottom-ash from different hospitals in Dares Salaam
2020
[7] Assessment of air pollutant emissions from healthcare waste incinerators of different design features
2020
[8] Правовые и экономические проблемы совершенствования системы управления медицинскими отходами
2020

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.