Open Journal of Orthopedics

Volume 5, Issue 10 (October 2015)

ISSN Print: 2164-3008   ISSN Online: 2164-3016

Google-based Impact Factor: 0.25  Citations  h5-index & Ranking

The Accuracy of Initial Bone Cutting in Total Knee Arthroplasty

HTML  XML Download Download as PDF (Size: 1026KB)  PP. 297-304  
DOI: 10.4236/ojo.2015.510040    3,887 Downloads   5,163 Views  Citations

ABSTRACT

Background: The aim of this study was to evaluate the accuracy of initial bone cutting of the distal femur and the proximal tibia in TKA using an image-free navigation system. Methods: From February 2006 to March 2013, we evaluated 60 knees in 50 patients using an image-free navigation system (Navigation: Stryker Navigation Cart System; Software: Stryker Knee Navigation; Ver2.0: Stryker Orthopaedics US NJ Mahwah). First, we measured the angle shown by the navigation system before cutting, at the time we set the jig. Second, we measured the angles shown by navigation after the bone was cut using the jig. Then, we compared these two angles for each patient to determine the bone cutting error. Results: In the distal femur, 37 of 60 knees were cut in an extended position in the sagittal plane, and 26 of 60 knees were cut in a varus in the coronal plane. In the proximal tibia, 29 of 60 knees were cut with decreased posterior slope in the sagittal plane, and 26 of 60 knees were cut in a valgus. Conclusions: In this study, the distal femur tended to be cut in an extended and a varus position and the proximal tibia did with decreased posterior slope and in a valgus position after initial bone cutting. It is necessary to note the initial cutting error in TKA. Since cutting errors affect postoperative outcome, we should cut bones several times. And as the reasons of the cause of the error, we propose new reason that cutting bone is not parallel with accuracy to AP axis.

Share and Cite:

Ohmori, T. , Maeda, T. , Kabata, T. , Kajino, Y. , Iwai, S. and Tsuchiya, H. (2015) The Accuracy of Initial Bone Cutting in Total Knee Arthroplasty. Open Journal of Orthopedics, 5, 297-304. doi: 10.4236/ojo.2015.510040.

Cited by

[1] Primary total knee arthroplasty assisted by computed tomography-free navigation for secondary knee osteoarthritis following massive calcium phosphate …
BMC Musculoskeletal …, 2022
[2] Akihiko Takeuchi, Norio Yamamoto, Takaaki Ohmori, Katsuhiro Hayashi, Shinji Miwa, Kentaro Igarashi, Takashi Higuchi, Kensaku Abe, Hirotaka Yonezawa, Sei …
2022
[3] Bone cuts accuracy of a system for total knee arthroplasty including an active robotic arm
Journal of Clinical …, 2021
[4] The accuracy of the “projected surgical transepicondylar axis” relative to the “true surgical transepicondylar axis” in total knee arthroplasty
2017
[5] Accuracy of the Precision Saw versus the Sagittal Saw during total knee arthroplasty: A randomised clinical trial
2017
[6] The Knee Accuracy of the Precision Saw versus the Sagittal Saw during total knee arthroplasty: A randomised clinical trial
2017
[7] Case-related factors affecting cutting errors of the proximal tibia in total knee arthroplasty assessed by computer navigation
Knee Surgery, Sports Traumatology, Arthroscopy, 2016

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.