Patient Peak Skin Dose and Dose Area Product from Interventional Cardiology Procedures

HTML  XML Download Download as PDF (Size: 2746KB)  PP. 7-12  
DOI: 10.4236/ijmpcero.2015.41002    5,158 Downloads   6,385 Views  Citations

ABSTRACT

Information about the peak skin dose and Dose Area product (DAP) from percutaneous transluminal coronary angioplasty (PTCA) and coronary angiography (CA) was collected from three catheter application rooms. The range of maximum photon energy was 50 - 125 kVp and the fluoroscopy time was 0.6 - 52 seconds. Values of up to 143 Gy·cm2 for DAP and 0.752 mGy for cumulative dose (CD) were found in CA procedures. Otherwise the DAP and CD for PTCA were found to be 143 Gy·cm2 and 2.287 mGy respectively in 3rd Quartile. The relation between the fluoroscopy time and the DAP is also considered. Objectives: The objective of this study is to obtain information about patient peak skin doses (PSD), dose area product (DAP), Fluoroscopy Time (FT) and Cumulative Dose (CD) from PTCA and CA which is the most predominant with respect to high skin doses in addition to other procedures. The aim of this study is also to assess the radiation dose received by patients undergoing interventional radiology procedures, by identifying the procedures that deliver the highest doses. This study is also helpful to establish the reference dose level for adult patients undergoing interventional procedure, and to provide recommendations on how to reduce dose on selected procedures that have been identified to deliver patient dose values near the ICRP (International Commission on Radiological Protection) threshold values.

Share and Cite:

Aly, A. , Duhaini, I. , Manaa, S. , Tarique, S. , Kuniyil, S. and Naemi, H. (2015) Patient Peak Skin Dose and Dose Area Product from Interventional Cardiology Procedures. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 4, 7-12. doi: 10.4236/ijmpcero.2015.41002.

Cited by

[1] Local diagnostic reference levels and effective doses: single institution levels for interventional cardiology procedures for adult patients
Grelik, L Wojciuch - Polish Journal of Medical …, 2022
[2] Radiation Dose and Related Risk in Interventional Cardiology
2021
[3] Local Diagnostic Reference Levels in Interventional Radiology
2020
[4] Advanced Robotic Angiography Systems for Image Guidance During Conventional Transarterial Chemoembolization: Impact on Radiation Dose and Image Quality
2019
[5] Patient's Peak Skin Dose evaluation using Gafchromic films in interventional cardiology procedures and its correlation with other dose indicators
Physica Medica, 2018
[6] Interventional Cardiology-Eight Years of Practice: Do Increased Experience and Technological Evolution Lead to Undertaking More Difficult Cases and Higher …
2017
[7] Interventional Cardiology-Eight Years of Practice: Do Increased Experience and Technological Evolution Lead to Undertaking More Difficult Cases and Higher …
2017
[8] PATIENT DOSIMETRY DURING INTERVENTIONAL CARDIAC PROCEDURES IN A DEDICATED CATHETERIZATION LABORATORY
2016

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.