Advances in Breast Cancer Research

Volume 4, Issue 1 (January 2015)

ISSN Print: 2168-1589   ISSN Online: 2168-1597

Google-based Impact Factor: 0.46  Citations  

Observer Variability in BI-RADS Ultrasound Features and Its Influence on Computer-Aided Diagnosis of Breast Masses

HTML  XML Download Download as PDF (Size: 2989KB)  PP. 1-8  
DOI: 10.4236/abcr.2015.41001    3,806 Downloads   5,603 Views  Citations

ABSTRACT

Objective: Computer classification of sonographic BI-RADS features can aid differentiation of the malignant and benign masses. However, the variability in the diagnosis due to the differences in the observed features between the observations is not known. The goal of this study is to measure the variation in sonographic features between multiple observations and determine the effect of features variation on computer-aided diagnosis of the breast masses. Materials and Methods: Ultrasound images of biopsy proven solid breast masses were analyzed in three independent observations for BI-RADS sonographic features. The BI-RADS features from each observation were used with Bayes classifier to determine probability of malignancy. The observer agreement in the sonographic features was measured by kappa coefficient and the difference in the diagnostic performances between observations was determined by the area under the ROC curve, Az, and interclass correlation coefficient. Results: While some features were repeatedly observed, κ = 0.95, other showed a significant variation, κ = 0.16. For all features, combined intra-observer agreement was substantial, κ = 0.77. The agreement, however, decreased steadily to 0.66 and 0.56 as time between the observations increased from 1 to 2 and 3 months, respectively. Despite the variation in features between observations the probabilities of malignancy estimates from Bayes classifier were robust and consistently yielded same level of diagnostic performance, Az was 0.772-0.817 for sonographic features alone and 0.828-0.849 for sonographic features and age combined. The difference in the performance, ΔAz, between the observations for the two groups was small (0.003-0.044) and was not statistically significant (p < 0.05). Interclass correlation coefficient for the observations was 0.822 (CI: 0.787-0.853) for BI-RADS sonographic features alone and for those combined with age was 0.833 (CI: 0.800-0.862). Conclusion: Despite the differences in the BI-RADS sonographic features between different observations, the diagnostic performance of computer-aided analysis for differentiating breast masses did not change. Through continual retraining, the computer-aided analysis provides consistent diagnostic performance independent of the variations in the observed sonographic features.

Share and Cite:

Sultan, L. , Bouzghar, G. , Levenback, B. , Faizi, N. , Venkatesh, S. , Conant, E. and Sehgal, C. (2015) Observer Variability in BI-RADS Ultrasound Features and Its Influence on Computer-Aided Diagnosis of Breast Masses. Advances in Breast Cancer Research, 4, 1-8. doi: 10.4236/abcr.2015.41001.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.