American Journal of Analytical Chemistry

Volume 2, Issue 2 (May 2011)

ISSN Print: 2156-8251   ISSN Online: 2156-8278

Google-based Impact Factor: 1.71  Citations  h5-index & Ranking

Voltammetric Determination of Vitamin B6 at Glassy Carbon Electrode Modified with Gold Nanoparticles and Multi-Walled Carbon Nanotubes

HTML  Download Download as PDF (Size: 504KB)  PP. 194-199  
DOI: 10.4236/ajac.2011.22022    5,088 Downloads   10,552 Views  Citations

Affiliation(s)

.

ABSTRACT

In this work, the gold nanoparticles (Au NPs)/multi-walled carbon nanotubes (MWCNTs) composite film modified glassy carbon electrode (GCE) was fabricated, and scanning electron microscopy (SEM) was used to investigate the assemble process of the composite film. In pH 7.0 PBS, a oxidation peak of the vitamin B6 (VB6) was only observed at composite film modified electrode. Under the optimized conditions, the current intensity was linear with the concentrations of VB6 in the range of 1.59 to 102.74 μg●mL–1 with a detection limit of 0.53 μg●mL–1 (S/N = 3). The modified electrode had been applied in medication analysis, and obtained good results.

Share and Cite:

Y. Zhang and Y. Wang, "Voltammetric Determination of Vitamin B6 at Glassy Carbon Electrode Modified with Gold Nanoparticles and Multi-Walled Carbon Nanotubes," American Journal of Analytical Chemistry, Vol. 2 No. 2, 2011, pp. 194-199. doi: 10.4236/ajac.2011.22022.

Cited by

[1] Analytical Eco-Scale for Evaluating the Uniqueness of Voltammetric Method used for Determination of Antiemetic Binary Mixture Containing Doxylamine …
Hadi, BM Eltanany, HE Zaazaa… - Electrocatalysis, 2022
[2] A New Potentiomertic Sensor for a Preventing Alzheimer's Disease Drug Based on Nano-Silver Modified Carbon Paste Electrode
2021
[3] Novel, rapid, low-cost screen-printed (bio) sensors for the direct analysis of boar taint compounds androstenone and skatole in porcine adipose tissue: Comparison …
2019
[4] Investigations into Novel Electrochemical Technology for Boar Taint Detection and Vitamin Analysis
2018
[5] Development of Sulfolane Modified Electrode Sensor for the Determination of Vitamin-B6, Vitamin-C and Uric Acid
2017
[6] Validated Spectrophotometric Method to Assay of B6 and B3 Vitamins in Pharmaceutical Forms Using Potassium Iodide and Potassium Iodate
2015
[7] Validated Spectrophotometric Method to Assay of B^ sub 6^ and B^ sub 3^ Vitamins in Pharmaceutical Forms Using Potassium Iodide and Potassium Iodate
International Letters of Chemistry, Physics and Astronomy, 2015
[8] Validated Spectrophotometric Method to Assay of B^ sub 6^ and B^ sub 3^ Vitamins in Pharmaceutical Forms Using Potassium Iodide and Potassium …
2015
[9] New electrode architectures based on poly (methylene green) and functionalized carbon nanotubes: characterization and application to detection of acetaminophen and pyridoxine
Journal of Electroanalytical Chemistry, Elsevier, 2015
[10] Voltammetric determination of B1 and B6 vitamins using a pencil graphite electrode
Chemical Papers, 2015
[11] Voltammetric determination of B 1 and B 6 vitamins using a pencil graphite electrode
2015
[12] Electrochemically Reduced Graphene Oxide Modified Carbon Ceramic Electrode for the Determination of Pyridoxine
Analytical Chemistry Letters, 2014
[13] Voltammetric investigation of complex growth media at a bare glassy carbon electrode: A case study of oxytetracycline
Electrochimica Acta, Elsevier, 2014
[14] NOVEL DIAGNOSTIC TOOL TO DETECT VITAMIN B6 USING Fe3O4 MODIFIED GLASSY CARBON ELECTRODE: A RAPID TECHNIQUE TO ASSAY BIOCLINICAL SAMPLES
INTERNATIONAL JOURNAL OF UNIVERSAL PHARMACY AND BIO SCIENCES, 2013

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.