Journal of Biomedical Science and Engineering

Volume 7, Issue 9 (July 2014)

ISSN Print: 1937-6871   ISSN Online: 1937-688X

Google-based Impact Factor: 0.66  Citations  h5-index & Ranking

Flow Cytometer Performance Characterization, Standardization and Calibration against CD4 on T Lymphocytes Enables Quantification of Biomarker Expressions for Immunological Applications

HTML  XML Download Download as PDF (Size: 3268KB)  PP. 756-768  
DOI: 10.4236/jbise.2014.79074    5,325 Downloads   6,999 Views  Citations

ABSTRACT

There is an urgent need for developing a procedure for biomarker standardization and relative quantificationin clinical laboratories. Measuring the expression levels of cell antigens is critical for the diagnosis of many diseases, e.g. leukemia, lymphoma and immunodeficiency diseases. One of the most significant challenges in flow cytometry is obtaining inter-laboratory and intra-laboratory consistent and reproducible results across multiple cytometer platforms and locations longitudinally over time. To obtain measurement consistency, the target flow cytometer voltages should be optimized to segregate the negative population from the electronic noise, and to keep the brightest positive population within the dynamic range of each detector. Then target values should be determined and transferred to selected cytometers. In this study, we optimized a procedure for instrument standardization across three different flow cytometer platforms from the same vendor and in two different locations. The biomarker quantification was implemented on standardized instruments using CD4 expression on T lymphocytes with a known amount of antibody bound per cell as a quantification standard. Our results on blood cell subset typing and CD19 quantification demonstrated that consistent and reliable results could be accomplished between instruments using the developed procedure. Quantitating the expression levels of certain cell biomarkers relative to a known reference marker before, during, and after therapy would provide important information for monitoring antibody-based therapy and could be potentially used to adjust dosing. Presently, we are implementing this protocol to quantify critical disease biomarkers, and making necessary modifications to the procedure to include instruments from different instrument manufacturers.

Share and Cite:

Degheidy, H. , Bauer, S. , Marti, G. and Wang, L. (2014) Flow Cytometer Performance Characterization, Standardization and Calibration against CD4 on T Lymphocytes Enables Quantification of Biomarker Expressions for Immunological Applications. Journal of Biomedical Science and Engineering, 7, 756-768. doi: 10.4236/jbise.2014.79074.

Cited by

[1] Guidelines for standardizing T‐cell cytometry assays to link biomarkers, mechanisms, and disease outcomes in type 1 diabetes
European journal of …, 2022
[2] Multi-centre validation of a flow cytometry method to identify optimal responders to interferon-beta in multiple sclerosis
2019
[3] Quantitative Fluorescence Measurements with Multicolor Flow Cytometry
Flow Cytometry Protocols, 2018
[4] Consistent, multi‐instrument single tube quantification of CD 20 in antibody bound per cell based on CD 4 reference
Cytometry Part A, 2016
[5] Quantitative Flow Cytometry Measurements in Antibodies Bound per Cell Based on a CD4 Reference
Current Protocols in Cytometry, 2016
[6] Quantification of cells with specific phenotypes II: Determination of CD4 expression level on reconstituted lyophilized human PBMC labelled with anti‐CD4 …
Cytometry Part A, 2015
[7] Quantification of cells with specific phenotypes II: Determination of CD4 expression level on reconstituted lyophilized human PBMC labelled with anti‐CD4 FITC antibody
Cytometry Part A, 2015
[8] Recommendations for the development and validation of flow cytometry‐based receptor occupancy assays
Cytometry Part B: Clinical Cytometry, 2015
[9] Consistent, multi‐instrument single tube quantification of CD20 in antibody bound per cell based on CD4 reference
Cytometry Part B: Clinical Cytometry, 2015
[10] Quantification of cells with specific phenotypes II: Determination of CD4 expression level on reconstituted lyophilized human PBMC labelled with anti‐CD4 FITC …
Cytometry Part A, 2015

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.