World Journal of Cardiovascular Diseases

Volume 4, Issue 6 (May 2014)

ISSN Print: 2164-5329   ISSN Online: 2164-5337

Google-based Impact Factor: 0.38  Citations  

Anticoagulation in Pregnant Women with Mechanical Heart Valve Prostheses: 25-Year Experience at a Tertiary Care Hospital in a Developing Country

HTML  Download Download as PDF (Size: 261KB)  PP. 287-293  
DOI: 10.4236/wjcd.2014.46037    3,293 Downloads   4,735 Views  Citations

ABSTRACT

The aim of this retrospective study was to compare the different anticoagulation regimens used in pregnant women with prosthetic heart valves. We reviewed 86 pregnancies in 57 women from 1987 to 2011. The patients were divided into two groups: group A (39 pregnancies) had oral acenocoumarol throughout pregnancy; and in group B (47 pregnancies), acenocoumarol was replaced by subcutaneous heparin during the first trimester. Both groups received heparin at the time of delivery. The valves replaced were mitral (59.65%), aortic (12.28%), or both (28.07%). 74 pregnancies (86.04%) resulted in live births, 9 (10.46%) had stillbirths, 1 (1.16%) had spontaneous abortion and 2 (2.32%) underwent therapeutic abortions. The live birth rate was higher in women on heparin (87.23%) compared with those on acenocoumarol (84.61%). No malformations appeared in the 74 newborns, except for one case of hydrocephalus. There was one maternal death due to acute mitral valvular thrombosis while on heparin in the first trimester. Hemorrhagic complications occurred in 13 patients in the postpartum period, 4 of whom required transfusion. No anticoagulant regimen can be said to be entirely safe for use during pregnancy as there is a degree of risk with each regimen. Heparin does not offer a clear advantage over oral anticoagulation in the pregnancy outcome.

Share and Cite:

Tounsi, A. , Abid, D. , Louati, D. , Mallek, S. , Akrout, M. , Abid, L. , Abdennadher, M. , Frikha, I. , Chaabene, K. , Hentati, M. and Kammoun, S. (2014) Anticoagulation in Pregnant Women with Mechanical Heart Valve Prostheses: 25-Year Experience at a Tertiary Care Hospital in a Developing Country. World Journal of Cardiovascular Diseases, 4, 287-293. doi: 10.4236/wjcd.2014.46037.

Cited by

[1] Continued use of Warfarin in lower dose has safe maternal and neonatal outcomes in pregnant women with Prosthetic Heart Valves
2021
[2] Pregnancy Outcomes in Patients with Heart Valve Replacement: Sohag Perspective
2021
[3] Pregnancy and prosthetic heart valves: A case series
2019
[4] Impact of prosthetic heart valves on pregnancy in Bangladeshi women
2019
[5] Follow-up and management of valvular heart disease patients with prosthetic valve: a clinical practice guideline for Indian scenario
2019
[6] The Effect of Nicoumalone on Embryogenesis: A Retrospective Study
2018
[7] Annals of Obstetrics and Gynecology
2018
[8] Problématique de l'anticoagulation durant la grossesse: étude portant sur 30 gestantes porteuses de prothèses cardiaques mécaniques
Annales de Cardiologie et d'Angéiologie, 2018
[9] Maternal and fetal outcome among pregnant women following open heart surgery
2017
[10] Maternal and Fetal Outcomes in Pregnant Women with a Prosthetic Mechanical Heart Valve
Clinical Medicine Insights. Cardiology, 2016

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.