Journal of Environmental Protection

Volume 2, Issue 2 (April 2011)

ISSN Print: 2152-2197   ISSN Online: 2152-2219

Google-based Impact Factor: 1.15  Citations  h5-index & Ranking

Removal of Nitrogen Dioxide and Sulfur Dioxide from Air Streams by Absorption in Urea Solution

HTML  Download Download as PDF (Size: 463KB)  PP. 175-185  
DOI: 10.4236/jep.2011.22020    10,243 Downloads   24,729 Views  Citations

Affiliation(s)

.

ABSTRACT

The study focuses on the absorption rates of NO2, SO2 and a mixture of these two acid gases into urea solution in packed bed column. The absorption rate was studied as a function of absorbent temperature, urea concentration and acid gas concentration. The influence of liquid temperature between 10 - 40?C, urea concentration between 0.1 - 0.5 M and acid gas concentration NO2 between 100 - 1000 ppm (191 - 1910 mg/m3), SO2 between 500 - 2500 ppm (1310 - 6530 mg/m3) were investigated. The mass gas flow rate of 20.646 (kg/m2.min) at 25?C and the absorption rate were determined by measuring the NO2 and SO2 concentrations in the inlet and outlet streams of the absorptioncolumn. The absorption rate of SO2 increases with the decrease of temperature of absorbent (urea solution) and with the increase of the urea concentration. The presence of NO2 in the effluent gas stream lowers the absorption rate of SO2 in urea solution due to the fast reaction of NO2 with urea as compared with SO2. The absorption rate of NO2 decreases as the urea concentration exceeds 0.4 mol/l and for NO2 gas concentration of 100 ppm due to the decrease the diffusivity of the gas. The experimental data were analyzed using dimensionless analysis to find the correlation of mass transfer coefficient in the packed column Sh (H / dp)1.2 = 4.19*10–2 *(G' dp / μg)0.87 (μg / ρg DAB)0.60 The results confirmed the hypothesis that the absorption is accompanied with chemical reaction. Also it is found the increasing the temperature of absorbent solution the absorption rate of two gases is decreases. The mass transfer coefficient models are in good agreements with the Kramer’s equation.

Share and Cite:

M. Barbooti, N. Ibraheem and A. Ankosh, "Removal of Nitrogen Dioxide and Sulfur Dioxide from Air Streams by Absorption in Urea Solution," Journal of Environmental Protection, Vol. 2 No. 2, 2011, pp. 175-185. doi: 10.4236/jep.2011.22020.

Cited by

[1] Wet Scrubber for Coal Combustion with The Use of Textile Wastewater Feeding
2020
[2] Selective catalytic reduction of NO, sub> x with ammonia (NH 3-SCR) over transition metal-based catalysts-influence of the catalysts support
2019
[3] Two-Staged Dielectric Barrier Discharge-Urea Configuration for the Removal of NO of NOx in a Simulated Coal-Combustion Flue Gas
2019
[4] Selective catalytic reduction of NOx with ammonia (NH3-SCR) over transition metal-based catalysts-influence of the catalysts support.
2019
[5] Selective catalytic reduction of NOX with ammonia NH3-SCR over transition metal-based catalysts-influence of the catalysts support
… Problems of Mineral …, 2019
[6] CFD Model to Analyze SO2 Absorption in a Seawater Droplet
International Journal of …, 2019
[7] Various Technologies for Simultaneous Removal of NOx and SO2 from Flue Gas
2017
[8] 배출가스의 질소산화물과 이산화황 동시 저감 기술
2017
[9] SO2 removal by seawater in a spray tower: Experimental study and mathematical modeling
Chemical Engineering Research and Design, 2016
[10] SO 2 removal by seawater in a spray tower: Experimental study and mathematical modeling
Chemical Engineering Research and Design, 2016
[11] Environmental Chemistry
Environmental Applications of Instrumental …, 2015
[12] Fundamentals Of Chemical Analysis
2015
[13] SO2 Removal by Seawater in a Packed–Bed Tower: Experimental Study and Mathematical Modeling
Separation Science …, 2014
[14] Absorption of Nitrogen Dioxide into Sodium Carbonate Solution in Packed Column
JG Majeed - ijmer.com, 2014
[15] Volumetric Mass Transfer Coefficient of SO^ sub 2^ Gas Absorption into Aqueous Sodium Sulphite Solution in Plate Column
Modern Applied Science, 2014
[16] Volumetric Mass Transfer Coefficient of SO2 Gas Absorption into Aqueous Sodium Sulphite Solution in Plate Column
Modern Applied Science, 2013
[17] Circulating regeneration and resource recovery of flue gas desulfurization residuals using a membrane electroreactor: from lab concept to commercial scale
Environmental science & …, 2012
[18] Experimental Study of FGD by Seawater: Spray Tower Versus Packed Tower

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.