ABSTRACT

Accidents involving industrial radiography are the most frequent cause of severe or fatal overexposure to workers and the public. On May 5, 2000, a radiation accident happened at a construction site in a gamma radiography practice at the village of Meet Halfa-Egypt. The accident was a severe overdose of non-radiation workers due to external exposure of Ir-192. This paper provides a methodology for calculating doses and dose rates from the most commonly used industrial γ-sources: 192Ir, 60Co, 134Cs, 137Cs and 131I. For this purpose, MCNP computer code based on Monte Carlo technique is used. The applied method helps firstly in studying and analyzing the doses from the above mentioned sources. Secondly, it provides a lead container design in a trial to reduce the dose rate within the permissible. Computer models were used to simulate the 192Ir Meet Halfa accident. To verify these models, the calculated doses were compared with a well-known empirical formula to convert source activity into dose rate and then the models were applied at different distances to analyze the factors that affect the deposited dose in the human body to find out the dose received by the victims.

Share and Cite:

Massoud, E. (2014) Dose Assessment for Some Industrial Gamma Sources with an Application to a Radiation Accident. Open Journal of Modelling and Simulation, 2, 4-11. doi: 10.4236/ojmsi.2014.21003.

Cited by

[1] A Mercury (II) Oxide Dosimeter for Locating the Radioactive Source in Industrial Radiography Equipment
2020
[2] Characterization of a HgI2 Dosimeter for the Monitoring System of Position Detection of Radioactive Sources in Gamma-Ray Projector
2020
[3] Characterization of a new dosimeter for the development of a position-sensitive detector of radioactive sources in industrial NDT equipment
Journal of Instrumentation, 2018
[4] The Study on Design of Semiconductor Detector for Checking the Position of a Radioactive Source in an NDT
2017
[5] The Study on Design of lead monoxide based radiation detector for Checking the Position of a Radioactive Source in an NDT
2017
[6] 비파괴검사 분야에서 방사선원의 위치 확인을 위한 산화납 기반 방사선 검출기 설계에 관한 연구
2017
[7] ASSESSMENT OF REINFORCED CONCRETE BUILDINGS FOR ATTENUATION OF GAMMA RAY EMITTED FROM DIFFERENT SOURCES
2017

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.