World Journal of Cardiovascular Diseases

Volume 3, Issue 6 (September 2013)

ISSN Print: 2164-5329   ISSN Online: 2164-5337

Google-based Impact Factor: 0.38  Citations  

Comparison of pre-dilation with a non-compliant balloon versus a dual wire scoring balloon for coronary stenting

HTML  Download Download as PDF (Size: 261KB)  PP. 395-400  
DOI: 10.4236/wjcd.2013.36061    5,306 Downloads   9,109 Views  Citations

ABSTRACT

Purpose: The aim of this study was to determine the influence of lesion preparation using the dual wire scoring balloon on stent expansion and long-term outcomes. Methods: Forty-six consecutive de novo lesions treated with a single >2.5 mm drug-eluting stent under intravascular ultrasound guidance, using two implantation strategies, were randomly assigned to: 1) pre-dilation with a non-compliant balloon (NC group; n = 23) or 2) pre-dilation with a dual wire scoring balloon (DS group; n = 23). Results: Although the balloon size and the maximal dilation pressure for pre-dilatation was larger (3.33 ± 0.28 vs 3.09 ± 0.33 mm, p = 0.01) and higher (11.6 ± 3.2 vs 8.6 ± 2.7 atm, p < 0.01) in the NC group than the DS group, there were no significant differences in the stent expansion. Quantitative coronary angiography at the follow-up demonstrated a smaller in-stent late loss (0.71 ± 0.63 mm vs 0.23 ± 0.52 mm, p = 0.03) in the DS group. During the long-term follow-up, there were no significant differences in the major adverse cardiac event rates. Conclusions: Lesion preparation with a dual wire scoring balloon prior to drug-eluting stent implantation might therefore be a more feasible strategy than that using a non-compliant balloon.

Share and Cite:

Sadamatsu, K. , Yoshida, K. , Yoshidomi, Y. , Koga, Y. , Amari, K. and Tokunou, T. (2013) Comparison of pre-dilation with a non-compliant balloon versus a dual wire scoring balloon for coronary stenting. World Journal of Cardiovascular Diseases, 3, 395-400. doi: 10.4236/wjcd.2013.36061.

Cited by

[1] Contemporary Management of Severely Calcified Coronary Lesions
Journal of Personalized …, 2022
[2] Material Selection
Interventional …, 2022
[3] A Brief Review of Different Techniques to Treat Calcified Coronary Lesions
IAR Journal of Medical Case Reports, 2021
[4] Coronary Artery Calcification: From Cell to Stent—A Review
2021
[5] Treatment Procedures for Calcified Coronary Artery Lesions: A Juxtaposing Review of Intravascular Lithotripsy and Rotational Atherectomy
2021
[6] Procedural effectiveness with a focused force scoring angioplasty catheter: Procedural and clinical outcomes from the Scoreflex NC trial
2021
[7] Current Treatment Modalities for Calcified Coronary Artery Disease: A Review Article Comparing Novel Intravascular Lithotripsy and Traditional Rotational …
2020
[8] Contemporary Approach to Heavily Calcified Coronary Lesions
2019
[9] Intimal disruption affects drug-eluting cobalt-chromium stent expansion: A randomized trial comparing scoring and conventional balloon predilation
International Journal of Cardiology, 2016
[10] Impact of Implantation Technique and Plaque Morphology on Strut Embedment and Scaffold Expansion of Polylactide Bioresorbable Scaffold–Insights From ABSORB …
Circulation Journal, 2016
[11] Impact of Implantation Technique and Plaque Morphology on Strut Embedment and Scaffold Expansion of Polylactide Bioresorbable Scaffold–Insights From ABSORB …
2016

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.