ABSTRACT

Our purpose in this study was to assess the dosimetric impact of the Acuros XB algorithm (AXB), in comparison with Anisotropic Analytical Algorithm (AAA) calculations, for esophageal cancer treatment plans created with RapidArc technique. First, we performed a phantom study by comparing the percent depth dose (PDD) calculated by AXB and AAA against the measured PDD in a slab phantom containing a 2 cmair gap thickness. Second, we performed a clinical study using a computed tomography (CT) data set from 10 esophageal cancer patients. The treatment plans calculated by AXB and AAA were evaluated for planning target volume (PTV) coverage, doses to the PTV and organs at risk (OARs). Dose calculations by the AXB and AAA were done for identical beam parameters. The AXB showed better agreement (within ±0.5%) with measurements than did the AAA (?4.9% to ?6.2%). In comparison to the AAA, the AXB predicted a higher maximum PTV dose (2.0%), but lower mean (1.1%) and minimum (2.5%) PTV doses as well as reduced PTV coverage (9.1%). The averaged mean doses to all OARs predicted by the AXB were lower (up to 3.6%), and the percentage of lungs volume receiving at least 20 and 5 Gy were lower by about 3.6% in the AXB plans compared to the AAA plans. The AXB is more accurate than the AAA for dose predictions when air medium is involved. The use of AXB is more likely to avoid dose overestimation or underestimation for the esophageal cancer treatment plans compared to AAA.

Share and Cite:

S. Rana, K. Rogers, S. Pokharel, T. Lee, D. Reed and C. Biggs, "Acuros XB Algorithm vs. Anisotropic Analytical Algorithm: A Dosimetric Study Using Heterogeneous Phantom and Computed Tomography (CT) Data Sets of Esophageal Cancer Patients," Journal of Cancer Therapy, Vol. 4 No. 1, 2013, pp. 138-144. doi: 10.4236/jct.2013.41019.

Cited by

[1] Dosimetric comparison and validation of Eclipse Anisotropic Analytical Algorithm (AAA) and AcurosXB (AXB) algorithms in RapidArc-based radiosurgery plans of …
Medical …, 2022
[2] The impact of dose calculation algorithm for SBRT lung cancer radiotherapy treatment
Iranian Journal of …, 2022
[3] Calculating the medium correction factor for the PTW-30013 ionization chamber
2021
[4] Bolus 下空腔对各向异性分析算法计算精度影响
2021
[5] Clinical impact of anisotropic analytical algorithm and Acuros XB dose calculation algorithms for intensity modulated radiation therapy in lung cancer patients
Sheshtawy… - Journal of X-Ray …, 2021
[6] Çoklu beyin metastazlarının stereotaktik radyocerrahi (SRS) tedavi planlarının dozimetrik olarak karşılaştırılması
2021
[7] Peripheral Photon Doses from Different Techniques Delivered in Prostate Radiotherapy: Experimental Measurements and TPS Calculations.
2020
[8] Wpływ algorytmów obliczających rozkłady dawek w radioterapii na prawdopodobieństwo miejscowego wyleczenia
2019
[9] A depth dose study between AAA and AXB algorithm against Monte Carlo simulation using AIP CT of a 4D dataset from a moving phantom
Reports of Practical Oncology & Radiotherapy, 2018
[10] Calculation of absorbed dose in radiotherapy by solution of the linear Boltzmann transport equations
2018
[11] The performance of the AAA and Acurox XB algorithms in the case of lung cancer
2018
[12] Dosimetric Evaluation of VMAT, IMRT, and Proton Treatment Techniques Targeting Borderline Resectable Pancreatic Cancer Lesions
ProQuest Dissertations Publishing, 2017
[13] AAA and AXB algorithms for the treatment of nasopharyngeal carcinoma using IMRT and RapidArc techniques
Medical Dosimetry, 2017
[14] DOSIMETRIC VERIFICATION IN PHOTON BEAMS FOR ACUROS XB ALGORITHM
2016
[15] The accuracy of the Acuros XB algorithm in external beam radiotherapy–a comprehensive review
International Journal of Cancer Therapy and Oncology, 2014
[16] Dosimetric Study of Coplanar and Non-Coplanar Intensity-Modulated Radiation Therapy Planning for Esophageal Carcinoma
International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 2013
[17] Radiobiological evaluation of dose calculation algorithms in RapidArc planning of esophageal cancer treatment plans
Journal of Solid Tumors, 2013

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.