Energy and Power Engineering

Volume 4, Issue 5 (September 2012)

ISSN Print: 1949-243X   ISSN Online: 1947-3818

Google-based Impact Factor: 0.66  Citations  

Design and Evaluation of Solar Inverter for Different Power Factor Loads

HTML  Download Download as PDF (Size: 1653KB)  PP. 324-329  
DOI: 10.4236/epe.2012.45042    8,140 Downloads   12,607 Views  Citations

ABSTRACT

This paper analyzes and compares the performance of a new inverter topology with two types of input sources: 1) Solar PV source and 2) Ideal dc source (battery). The simulation is done in SIMULINK/MATLAB Software. It is shown that when the solar panel is connected, spikes are obtained in output voltage waveforms. These spikes are eliminated by inserting a capacitor. The capacitor is chosen for a particular power factor which is optimum with respect to cost, size and power quality. Total Harmonic Distortion, Active Power, Reactive Power, RMS Voltage and RMS Current are measured for different load power factor. Finally these results are compared with those obtained using battery with same input voltage magnitude. This Paper shows that for Solar Panel Circuit, THD, P and Q are less for 0.8 and above power factor, however below 0.8 PF, the THD, active and reactive power transfer are more. This means that the performance of Solar Panel in the proposed circuit topology is seen to be better as compared to the same circuit with battery within a range of power factor.

Share and Cite:

M. Ahmad and B. Khan, "Design and Evaluation of Solar Inverter for Different Power Factor Loads," Energy and Power Engineering, Vol. 4 No. 5, 2012, pp. 324-329. doi: 10.4236/epe.2012.45042.

Cited by

[1] HARMONIC EMISSION OF 1KVA SOLAR-POWERED INVERTER UNDER NO-LOAD AND LOADING CONDITIONS WITH MITIGATION TECHNIQUES
2022
[2] Development of a Prototype Inverter Powered Baking Oven
Journal of Applied …, 2021
[3] Simulation and Analysis of an Improved Quality Multilevel Inverter for Linear Types of Load
2021 6th International …, 2021
[4] Implementation of a Distribution Static Compensator D-STATCOM: Hardware and Firmware Description
2019
[5] TEMİZ ENERJİ KAYNAKLARI VE DENİZCİLİK UYGULAMALARI CLEAN ENERGY SOURCES AND MARITIME APPLICATIONS
2019
[6] Modeling and real time optimization of a smart microgrid
2019
[7] Performance Analysis of a Solar PV based Grid Tied Multilevel Inverter Scheme for Linear and Non Linear Load
International Journal of Recent Technology and Engineering, 2019
[8] Harmonics Analysis Of A SPV Based Stand-Alone And Grid Connected Multilevel Inverter With Improved Power Quality At Different Load
INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH, 2019
[9] PERBANDINGAN FAKTOR DAYA PADA LAMPU HEMAT ENERGI DENGAN MENGGUNAKAN DAN TANPA MENGGUNAKAN INVERTER
2018
[10] Symmetric and Asymmetric Multilevel Inverter Topologies with Device Count: A Review
2018
[11] Simulation and performance analysis of a grid connected multilevel inverter considering either battery or solar PV as DC input sources
2017
[12] Improvisation Analysis of Reactive Power Energy Saving Lamps Based on Inverter
2017
[13] Photovoltaic Solar Farms Operating in VAR Mode: A Review
2016
[14] Techno-Economic Approach to Solar Energy Systems Onboard Marine Vehicles
Polish Maritime Research, 2016
[15] Comparative Analysis of Two Inverter Topologies Considering Either Battery or Solar PV as DC Input Sources
IOSR Journal of Electrical and Electronics Engineering, 2016

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.