World Journal of Nuclear Science and Technology

Volume 2, Issue 3 (July 2012)

ISSN Print: 2161-6795   ISSN Online: 2161-6809

Google-based Impact Factor: 0.38  Citations  h5-index & Ranking

Determination of Full Energy Peak Efficiency of NaI(Tl) Detector Depending on Efficiency Transfer Principle for Conversion Form Experimental Values

HTML  Download Download as PDF (Size: 626KB)  PP. 65-72  
DOI: 10.4236/wjnst.2012.23011    8,768 Downloads   17,865 Views  Citations

ABSTRACT

In this work we calibrated the NaI(Tl) scintillation detectors (5.08 × 5.08 cm2 and 7.62 × 7.62 cm2) and the Full Energy Peak Efficiency (FEPE) for these detectors have been calculated for point sources placed at different positions on the detector axis using the analytical approach of the effective solid angle ratio. This approach is based on the direct mathematical method reported by Selim and Abbas [1,2] and has been used successfully before to calibrate the cylindrical, parallelepiped, and 4π NaI(Tl) detectors by using point, plane and volumetric sources. In addition, the present method is free of some major inconveniences of the conventional methods.

Share and Cite:

M. Abd-Elzaher, M. Badawi, A. El-Khatib and A. Thabet, "Determination of Full Energy Peak Efficiency of NaI(Tl) Detector Depending on Efficiency Transfer Principle for Conversion Form Experimental Values," World Journal of Nuclear Science and Technology, Vol. 2 No. 3, 2012, pp. 65-72. doi: 10.4236/wjnst.2012.23011.

Cited by

[1] Material Identification Approach Based on the Counting Technique and Beam Hardening Correction Under Industrial X-Ray Computed Tomography: a Simulation …
Brazilian Journal of Physics, 2022
[2] Study the Effect of Weather Temperature on the Spectra of Gamma Rays for the Scintillation Detector Nai (Tl)
2021
[3] Simulation of Void Detection System using Gamma-Ray Compton Scattering Technique
2019
[4] A Quick Method to Calculate NaI (Tl) Detector Efficiency Depending on Gamma ray Energy and Source-to-detector Distance
Celal Bayar University Journal of Science, 2018
[5] A method to calculate the gamma ray detection efficiency of a cylindrical NaI (Tl) crystal
Journal of Instrumentation, 2018
[6] Source-to-detector Distance Dependence of Efficiency and Energy Resolution of a 3" x3" NaI (Tl) Detector
Avrupa Bilim ve Teknoloji Dergisi, 2018
[7] Water intakes of radiation damaged CR-39 radiation detector
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2018
[8] Detection of new polymer materials as gamma-ray-shielding materials
International Journal of Electronics, 2017
[9] Quantitative measurements of Rhenium-188 for radionuclide therapies
2017
[10] Effects of gamma irradiation on some chemicals using an NaI (Tl) detector
Radiation Effects and Defects in Solids, 2016
[11] Calculation of the full-energy peak efficiency of NaI (Tl) detector using the efficiency transfer method for large radioactive cylindrical sources
Chinese Journal of Physics, 2016
[12] Preliminary Study of Double Beta Decay: Simulation of CaMoO4 Scintillation Detector Response Function to the Gamma Ray Radiation
2016
[13] Accuracy, reproducibility, and uncertainty analysis of thyroid‐probe‐based activity measurements for determination of dose calibrator settings
Medical physics, 2016
[14] Effective Atomic Numbers for Some Low-Z Materials.
BIONANO FRONTIER, 2015
[15] The accurate extraction of photopeak intensities in the gamma-ray spectroscopy of naturally occuring radioactive materials
2015
[16] The Accurate Extraction of Photopeak Intensities in the Gamma-Ray Spectroscopy of Naturally Occurring Radioactive Materials
2015
[17] STUDY ON THE EFFECT OF THE SELF-ATTENUATION COEFFICIENT ON γ-RAY DETECTOR EFFICIENCY CALCULATED AT LOW AND HIGH ENERGY REGIONS
Nuclear Engineering and Technology, 2014
[18] Investigation of Incoherent Gamma-Ray Scattering Potential for the Fluid Density Measurement
Applied Mechanics and Materials, 2014
[19] An empirical formula to calculate the full energy peak efficiency of scintillation detectors
Applied Radiation and Isotopes. Elsevier, 2013
[20] Response Function of Collimated Detector for Non Axial Detector-Source Geometry
Advanced Materials Research, 2013
[21] Nuclear Track Detectors for Relativistic Nuclear Fragmentation Studies: Comparison with Other Competitive Techniques
Modern Instrumentation, 2013
[22] Solution of the Standard Source Lack in Quantitative Radioactive Samples Analysis
The Fourth Arab International Conference in Physics and Materials Science, 2012

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.