Circuits and Systems

Volume 3, Issue 3 (July 2012)

ISSN Print: 2153-1285   ISSN Online: 2153-1293

Google-based Impact Factor: 0.48  Citations  

Appropriate Placement of Fault Current Limiting Reactors in Different HV Substation Arrangements

HTML  Download Download as PDF (Size: 339KB)  PP. 252-262  
DOI: 10.4236/cs.2012.33035    13,134 Downloads   23,692 Views  Citations

ABSTRACT

Short circuit currents of power systems are growing with an increasing rate, due to the fast development of generation and transmission systems. Current Limiting Reactor is one of the effective short circuit current limiting devices. This technique is known to be more practical than other available approaches. In this paper, proper application of CLR to HV substations is proposed, based on a comprehensive short circuit analysis of 4 well-known substation bus bar arrangements. Eventually, appropriate place and number of CLRs is recommended for each bus bar arrangement.

Share and Cite:

H. Seyedi and B. Tabei, "Appropriate Placement of Fault Current Limiting Reactors in Different HV Substation Arrangements," Circuits and Systems, Vol. 3 No. 3, 2012, pp. 252-262. doi: 10.4236/cs.2012.33035.

Cited by

[1] Güç Sistemlerinde Arıza Akım Sınırlama Yöntemlerinin İncelenmesi Investigation of Fault Current Limiting Methods in Power Systems
[2] Limitation Analysis of 1st and 2nd Generation Superconductors used in Resistive Superconductor Fault Current Limiters
Journal of Engineering Research, 2022
[3] A Study of Encapsulation Temperature Field of Dry-type Air-core Reactor with the Structure of Equivalent and Aluminum Wire-Insulation
… & Alternative Energy …, 2022
[4] Modeling the limiting performance of resistive superconductor fault current limiters for 2G HTS tape
Firat University Journal of Experimental …, 2022
[5] Development and Testing of a 252 kV/2500 A-40 kA Multi-Break Bus-Coupler Fast Vacuum Circuit Breaker
Energies, 2021
[6] Integration of Fault Current Limiters in Electric Power Systems: A Review
2020
[7] A Study on Bangladesh Power System Fault Level Management
2019
[8] Development and Test of a 252 kV Multi-breaks Bus-tie Fast Vacuum Circuit Breaker
2019
[9] Reducing Short Circuit Level in 400kV Iraqi Grid System by Using FACTS Device
2019
[10] An effective approach to retrofit existing station service distribution systems in a hydroelectrical generating station
2018
[11] Evaluating the performance of unified power flow controller on fault current limitation in the Nigerian 330kV Power System
2018
[12] A Novel Five-Leg Design for Performance Improvement of Three-Phase Presaturated Core Fault-Current Limiter
2018
[13] Fault Current Limiters Types, Operations and its limitations
International Journal of Scientific and Engineering Research, 2018
[14] IGBT Based Bridge Type Fault Current Limiter
2018
[15] REDUCING SHORT CIRCUIT LEVELS BY USING SYSTEM SPLITTING STRATEGIES
2018
[16] Impact of shrubbery in rural transmission and distribution networks
2017
[17] Application of Facts Technology to Power System Protection in the Nigerian 330kv Network Using Genetic Algorithm
2017
[18] Study On Role And Applications Of IED In Smart Grid
2017
[19] ALTERNATIVAS PARA REDUCIR EL NIVEL DE CORTOCIRCUITO EN EL SISTEMA INTERCONECTADO CENTRAL (SIC) DE CHILE
2017
[20] Evaluating the Performance of Unified Power Flow Controller (UPFC) On Fault Current Limitation in the Nigrian 330kv Power System.
IOSR Journal of Electrical and Electronics Engineering, 2017
[21] Poboljšani metodi za merenje sigurnosnih karakteristika sistema uzemljenja u visokonaponskim postrojenjima
2016
[22] Statistically generalized rating for CLR in power transmission systems
2016
[23] A study on RC element based current limiter in AC Power Systems
2016
[24] A Comparitive study of CLR and CLCR as Current Limiters in AC Power Systems
2016
[25] Optimum selection of inductor as a current limiter in AC power systems
2016
[26] A comparative study of CLR and CLCR as Current Limiters in AC power systems
2016
[27] Investigation of fault current limiting methods in power systems
2016
[28] A New Approach to Implementing Fault Current Limiting Reactors (CLRS) On Feeders with Negligible Constant Power Losses
2015
[29] Impact Of Fault Current Limiters And Demand Response On Electric Utility Asset Management Programs
2015
[30] Implementation of bus bar switching and Short Circuit Constraints in optimal power flow problems
PowerTech, 2015 IEEE Eindhoven, 2015
[31] 1.1 DAR Structure
[32] Rezistif Süperiletken Arıza Akımı Sınırlayıcı MATLAB-Simulink Modeli ve Uygulaması-Son Hali

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.