Journal of Electromagnetic Analysis and Applications

Volume 1, Issue 1 (March 2009)

ISSN Print: 1942-0730   ISSN Online: 1942-0749

Google-based Impact Factor: 0.55  Citations  h5-index & Ranking

Some Advances in the Application of Weathering and Cold-Formed Steel in Transmission Tower

HTML  Download Download as PDF (Size: 7342KB)  PP. 24-30  
DOI: 10.4236/jemaa.2009.11005    6,660 Downloads   12,467 Views  Citations

ABSTRACT

Application of weathering and cold-formed steel in transmission lines can reduce steel consumption and environmental pollution. Some advances in the studies on the weathering and cold-formed steel in transmission tower are introduced. Firstly, corrosion-resistant tests of weathering steel samples under different simulating technical atmospheres were carried out separately for 240 hours. It shows that the corrosion degree of joint samples is higher than that of single chip samples, and the corrosion-resistant performance of weathering steel is superior to common carbon steel. The corrosion-resistance of weathering steel meets with the requirement of transmission tower. Secondly, experiments and finite element analysis for cold-formed angles and a 220kV prototype tower were completed, and the stability coeffi-cient fitting curves as well as the modification formulas of slenderness ratio for cold-formed members were determined. According to the structural characteristics of transmission towers, four sections of cold-formed angles with different sections and slenderness ratios were selected in this study. The finite element model well predicted the buckling behav-iour of the cold-formed members. Ultimate loads calculating by the fitting curve were well agreed to the experimental values, especially for the members with small slenderness ratios. Weight of the cold-formed steel tower can be reduced by more than 5 percent after considering the strength enhancement. Cost of the weathering and cold-formed steel transmission tower is nearly equivalent to that of hot-rolled steel tower with hot galvanizing.

Share and Cite:

F. Yang, J. Han, J. Yang and Z. Li, "Some Advances in the Application of Weathering and Cold-Formed Steel in Transmission Tower," Journal of Electromagnetic Analysis and Applications, Vol. 1 No. 1, 2009, pp. 24-30. doi: 10.4236/jemaa.2009.11005.

Cited by

[1] A study on weathering steel bolts for transmission towers
2020
[2] Development of hot rolled weathering angle steel for transmission towers
2019
[3] Assessment, Prevention And Remediation Of Corrosion In Weathering Steel Transmission Line Poles
2016
[4] Analysis and Design of 220kV transmission line tower with hot rolled and cold formed section
International Journal of Scientific & Engineering Research, 2015
[5] 输电杆塔钢构件腐蚀防护技术现状和发展趋势
山东电力技术, 2013
[6] Polynomial-based evaluation of the impact of aperture phase taper on the gain of rectangular horns
Journal of Electromagnetic Analysis and Applications, 2010
[7] Polynomial-Based Evaluation of the Impact of Aperture Phase Taper on the Gain of Rectangular Horns Open Access
KB Baltzis - scirp2.org, 2010

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.