ABSTRACT

This study investigated loads among five fixation types (FT) [three cannulated screws (CS), dynamic hip screws with and without derotational screws (DHS-DS and DHS), and dynamic helical hip screws with and without derotational screws (DHHS-DS and DHHS)] across three fracture moment lengths (ML) in Pauwels’ Type III fractures. Methods: Seventy-five sawbones were tested (5 FT × 5 trials × 3 ML). The study hypothesis was that significant differences in axial loading to failure would be demonstrated when CS was compared with the other four FT at the three MLs. Each construct was exposed to an axial compressive load to failure. Construct failure was defined as 5 mm of migration at the fracture site or fixation failure. Shapiro-Wilk was used to test for data normality. Subsequently, independent t-tests with Bonferroni correction was used for paired comparisons. Results: At fracture Moments A and B there were no statistical differences between CS and the other FT. At fracture Moment C all four FT yielded significantly higher (p ≤ 0.001) loads compared with CS. Conclusions: for basicervical fractures CS is a suboptimal form of fixation compared with DHS and DHHS both with and without derotation screws.

Share and Cite:

LePine, M. , Barfield, W. , DesJardins, J. and Hartsock, L. (2010) The effect of moment arm length on high angled femoral neck fractures (Pauwels’ III). Journal of Biomedical Science and Engineering, 3, 448-453. doi: 10.4236/jbise.2010.35062.

Cited by

[1] Hybrid triad provides fracture plane stability in a computational model of a Pauwels Type III hip fracture
2020
[2] Medial Plating of Pauwels Type III Femoral Neck Fractures Decreases Shear and Angular Displacement Compared with a Derotational Screw
2020
[3] Interfragmentary motion assessment for three different fixation techniques of femoral neck fractures in young adults
Bio-Medical Materials and Engineering, 2016
[4] A computational orthopaedic biomechanics study of osteoporotic hip fractures
2016
[5] Comparison of Three Fixation Methods for Femoral Neck Fracture in Young Adults: Experimental and Numerical Investigations
Journal of Medical and Biological Engineering, 2015
[6] Influence of number and orientation of screws on stability in the internal fixation of unstable femoral neck fractures.
2014
[7] Influence of number and orientation of screws on stability in the internal fixation of instable femoral neck fractures
Acta Orthopaedica et Traumatologica Turcica, 2014
[8] Influence of number and orientation of screws on stability in the internal fixation of unstable femoral neck fractures
Acta orthopaedica et traumatologica turcica, 2014
[9] İnstabil femur boyun kırıklarının internal tespitinde vida sayısı ve yöneliminin stabiliteye etkisi
2014
[10] 采用股骨近端防旋髓内钉治疗老年无移位型股骨颈骨折(12 例报告)
中国矫形外科杂志, 2013

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.