Journal of Environmental Protection

Volume 3, Issue 2 (February 2012)

ISSN Print: 2152-2197   ISSN Online: 2152-2219

Google-based Impact Factor: 1.15  Citations  h5-index & Ranking

Ultraviolet Radiation for Microorganism Inactivation in Wastewater

HTML  Download Download as PDF (Size: 174KB)  PP. 194-202  
DOI: 10.4236/jep.2012.32024    6,089 Downloads   10,299 Views  Citations

ABSTRACT

The purpose of this research stream is to evaluate the kinetics of bacterial strains of Pseudomonas aeruginosa, to establish the influence of UV doses on the kinetics of disinfection, to study UV-resistant strains of Pseudomonas aeruginosa, and to underline the influence of suspended solids on the inactivation kinetics of these strains. Furthermore, and due to the lack of readily available information about the influence of temperature on microorganism inactivation processes subsequent to inactivation with UV radiation, a series of batch studies were performed at 5℃, 25?C, 37.5℃ and 50℃. This paper investigates the impact of UV irradiation on bacterial strains of P. aeruginosa inactivation in both primary and secondary wastewater effluents and to show the influence of filtration in the process of disinfection of water by UV irradiaton. Our results indicate that the effect of temperature within the normal operating range of most treatment plants, i.e., 25℃ to 37.5℃, was found to be not statistically significant on the kinetics of the UV disinfection process. However, the kinetics of the UV disinfection process was highly affected by system operating at extreme temperatures, i.e., at 10 and 50℃. In a temperature range of 25℃ to 37.5℃, the inactivation of P. aeruginosa strains varied according to the incubation time and did not exceed 4 U-Log. Consequently, having more than 102 organisms/100ml of P. aeruginosa in treated wastewater would cause serious health and environmental problems. Low inactivation was observed when the operating temperature was reduced to 10℃ regardless of the incubation time tested. In contrast, a considerable increase in the inactivation rate was noted when the temperature of the disinfected wastewater was increased to 50℃. Hence, as 5℃ and 50℃ are outside the operating range of most treatment plants, as in our country, Tunisia, it is reasonable to assume that the effect of temperature change on the kinetics of UV disinfection process is negligible.

Share and Cite:

B. Mounaouer and H. Abdennaceur, "Ultraviolet Radiation for Microorganism Inactivation in Wastewater," Journal of Environmental Protection, Vol. 3 No. 2, 2012, pp. 194-202. doi: 10.4236/jep.2012.32024.

Cited by

[1] Applicability of bio-synthesized nanoparticles in fungal secondary metabolites products and plant extracts for eliminating antibiotic-resistant bacteria risks in non …
Environmental …, 2022
[2] Investigation of mouse hepatitis virus strain A59 inactivation under both ambient and cold environments reveals the mechanisms of infectivity reduction following UVC …
Journal of environmental …, 2022
[3] Water Disinfection Techniques: A review
2021
[4] Strategi Penurunan Pencemaran Perairan Akibat Limbah Pabrik dengan Pembuatan Resirkulasi Air Sistem Biofilter Anaerob-Aerob di Desa Burai, Sumatera Selatan
Seminar Nasional …, 2021
[5] Disinfection of wastewater by UV-based treatment for reuse in a circular economy perspective. where are we at?
2021
[6] Performance evaluation of combined ultraviolet-ultrasonic technologies in removal of sulfonamide and tetracycline resistant Escherichia coli from domestic effluents
2020
[7] Efficacy of integrated ultraviolet ultrasonic technologies in the removal of erythromycin-and quinolone-resistant Escherichia coli from domestic wastewater through a …
2019
[8] Utilisation of appropriately treated wastewater for some further beneficial purposes: a review of the disinfection method of treated wastewater using UV radiation …
2019
[9] Efficacy of integrated ultraviolet ultrasonic technologies in the removal of erythromycin- and quinolone-resistant Escherichia colifrom domestic wastewater througha laboratory-based experiment
Journal of Water, Sanitation and Hygiene for Development, 2019
[10] Evaluating the disinfection efficacy of low-pressure ultraviolet irradiation on river water
2019
[11] WATER USE PRACTICES, WATER QUALITY AND PERFORMANCE OF A CONTINUOUS SOLAR WATER DISINFECTION SYSTEM IN ISIOLO COUNTY …
Thesis, 2018
[12] Effect of ultraviolet radiation on the growth of microorganisms developing on cave wall paintings
AIP Conference Proceedings, 2018
[13] Generation of Intense UV Radiation during High-Current Breakdown over a Ferrite Surface
2018
[14] Assessment of UV-C-induced water disinfection by differential PCR-based quantification of bacterial DNA damage
Journal of Microbiological Methods, 2018
[15] ГЕНЕРАЦИЯ МОЩНОГО УФ-ИЗЛУЧЕНИЯ ПРИ ПОВЕРХНОСТНОМ СИЛЬНОТОЧНОМ ПРОБОЕ ФЕРРИТА
2018
[16] Water use practices, water quality and performance of a continuous solar water disinfection system in Isiolo County, Kenya
2018
[17] Ultraviolet Disinfection Pilot Study at the Fargo Wastewater Treatment Plant
2017
[18] Model Reference Following Control of a UV Water Disinfection System
2017
[19] Pengukuran Serapan Ultraviolet Pada Kaca Film Menggunakan Sensor UVM-30A Berbasis Mikrokontroler Atmega8535
2017
[20] Removal of E. coli and S. aureus from polluted water using electrolysis method with Al-Fe electrodes
2017
[21] حذف باکتری‌های اشرشیاکلی و استافیلوکوکوس اورئوس از آب آلوده به‌روش الکترولیز با الکترودهای آلومینیم-آهن‎
2017
[22] Multivariable model of an ultraviolet water disinfection system
2017
[23] Nanoparticles and their potential application as antimicrobials in the food industry
Food Preservation, 2017
[24] Design and Control of an Ultraviolet Water Disinfection System Powered by Photovoltaic Source
2017
[25] Modeling and kinetic characterization of wastewater disinfection using chlorine and UV irradiation
Environmental Science and Pollution Research, 2016
[26] Effects of salinity and temperature on inactivation and repair potential of Enterococcus faecalis following medium‐ and low‐pressure ultraviolet irradiation
Journal of applied microbiology, 2016
[27] PEMBUATAN DISK KARBON AKTIF SEBAGAI MEDIA FILTRASI MENGGUNAKAN CAMPURAN POLYETHERSULFONE
2016
[28] Optimization electrophotocatalytic removal of Streptococcus faecalis from water by Taguchi model
Journal of Pure and Applied Microbiology, 2015
[29] Pseudomonas aeruginosa removal from water using electrophotocatalytic method
International Journal of Microbiology and Immunology Research, 2015
[30] Minimization of water consumption in fresh-cut salad washing by UV-C light
Food Control, 2015
[31] Quantifying ultraviolet inactivation kinetics in nearly opaque fluids
Journal of Photochemistry and Photobiology A: Chemistry, 2015
[32] Flood disaster water treatment solution from existing and common ideas with two versions of MSWT–01
International Journal of Industrial and Systems Engineering, 2015
[33] Reducing pathogens in combined sewer overflows using ozonation or UV irradiation
International journal of hygiene and environmental health, 2015
[34] Efficient management of the water resource in the fresh-cut industry: current status and perspectives
Trends in Food Science & Technology, 2015
[35] Effects of Salinity and Temperature on Inactivation and Repair Potential of Enterococcus Faecalis following Medium‐and Low‐Pressure Ultraviolet Irradiation
Journal of Applied Microbiology, 2015
[36] Flood disaster water treatment solution from existing and common ideas with two versions of MSWT-01
International Journal of Industrial and Systems Engineering, 2015
[37] Attempt of simulation of models to predict the disinfection efficacy of an UV disinfection reactor and kinetic study of inactivation of selected bacteria of …
2014
[38] Modeling of ultraviolet (UV) radiation under a large pilot-scale designed for wastewater disinfection and inactivation of selected bacteria of Pseudomonas aeruginosa …
2014
[39] Attempt of simulation of models to predict the disinfection efficacy of an UV disinfection reactor and kinetic study of inactivation of selected bacteria of Pseudomonas …
2014
[40] Attempt of simulation of models to predict the disinfection efficacy of an UV disinfection reactor and kinetic study of inactivation of selected bacteria of Pseudomonas aeruginosa in a laboratory UV device
African Journal of Microbiology Research, 2014
[41] Modeling of ultraviolet (UV) radiation under a large pilot-scale designed for wastewater disinfection and inactivation of selected bacteria of Pseudomonas aeruginosa in a laboratory UV device
African Journal of Microbiology Research, 2014
[42] INACTIVATION AND REPAIR OF ENTEROCOCCUS FAECALIS AND VIBRIO CHOLERA BY UV FOR BALLAST WATER TREATMENT
2014
[43] Attempt of simulation of models to predict the disinfection efficacy of an UV disinfection reactor and kinetic study of inactivation of selected bacteria of …
African Journal of Microbiology Research, 2014
[44] Modeling of ultraviolet (UV) radiation under a large pilot-scale designed for wastewater disinfection and inactivation of selected bacteria of Pseudomonas …
African Journal of Microbiology …, 2014
[45] Disinfection of Water by UV Irradiation-Modeling and Improvement
Current Biotechnology, 2012
[46] FABRICATION OF ACTIVATED CARBON DISC AS FILTRATION MEDIA UTILIZING POLYETHERSULFONE
[47] Research Paper Efficacy of integrated ultraviolet ultrasonic technologies in the removal of erythromycin-and quinolone-resistant Escherichia coli from domestic …

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.