Open Access Library Journal

Volume 9, Issue 9 (September 2022)

ISSN Print: 2333-9705   ISSN Online: 2333-9721

Google-based Impact Factor: 0.73  Citations  

Simulation of Factors Affecting the Detection Efficiency of the Full Energy Peak of Lanthanum Bromide Detector

HTML  XML Download Download as PDF (Size: 1583KB)  PP. 1-7  
DOI: 10.4236/oalib.1109208    29 Downloads   291 Views  

ABSTRACT

Monte Carlo software MCNP and Geant4 were used to study the factors affecting the detection efficiency of the lanthanum bromide detector, mainly including the thickness of the detector al shell and the size of the crystal. The results of the two softwares were compared. The results show that only the thickness of the front Al shell increases the detection efficiency of the full energy peak, and the side al shell has little effect on the detection efficiency of the full energy peak; The increase of the radius length of the lanthanum bromide crystal will also increase the detection efficiency of the full energy peak. Comparing the results of MCNP and Geant4 simulation, it is found that the relative error of the two data is within 1%.

Share and Cite:

Dai, G.M., Zhou, Z.Q., Yuan, Q., Liao, G.H. and Yan, D.S. (2022) Simulation of Factors Affecting the Detection Efficiency of the Full Energy Peak of Lanthanum Bromide Detector. Open Access Library Journal, 9, 1-7. doi: 10.4236/oalib.1109208.

Cited by

No relevant information.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.