ABSTRACT

Solar water heaters which provide a cost-effective and environmental friendly approach to hot water generation are in widespread application. Evacuated tube solar water heaters perform better than flat plate solar water heaters as a result of their greater surface area exposed for sunlight absorption. Water-in-glass evacuated tube solar water heaters are widely used as compared to heat-pipe solar water heaters due to their short payback periods. In this study, the performance of water-in-glass evacuated tube solar water heater is investigated through experiments under the climatic conditions in Kenya. The results revealed a daily efficiency range of 0.58 - 0.65 and a daily final outlet temperature greater than 55°C given an initial temperature of 25°C.