Occupational Eye Lens Radiation Dose While Performing Interventional Procedures over 18 Months Using a Face-Shield Equipped Suspended Radiation Protection System

HTML  XML Download Download as PDF (Size: 831KB)  PP. 101-114  
DOI: 10.4236/ojrad.2020.102011    759 Downloads   2,123 Views  Citations

ABSTRACT

Background: Numerous studies have demonstrated increasing evidence for cataractogenesis at lower levels of ionizing radiation than previously believed, with some suggesting possible absence of a threshold. Genetic differences between individuals also result in increased susceptibility in some operators, who might not be aware. European occupational exposure limits have been reduced and operators are seeking protective measures. Objective: To evaluate the protective effect of a face-shield equipped suspended protection system (Zero-Gravity®, TIDI Products, Neenah, WI) along with adherence to safety practices against radiation dose to the eye lens for an interventional radiologist performing a wide variety of procedures. Materials and Methods: In this institutional review board-approved single-institution study, one interventional radiologist wore a highly sensitive personnel monitoring dosimeter badge on the cap near the left eye while performing 299 procedures (3690 fluoroscopy minutes) over 18 consecutive months while utilizing the suspended protection system along with adherence to other generally recommended safety practices and movement away from the field during angiographic power injections. Dosimetry reports and procedural information were retrospectively reviewed. Results: Total lens dose equivalent to the left eye over 18 months was 0.11 mSv (annualized dose = 0.073 mSv, or 7.3 mRem). The patient-dose-area product standardized dose of 0.00576 μSv/Gycm2 is well below reports of conventional lead aprons, shields, and protective eyewear. Conclusion: Eye exposures were kept to near-background levels using the materials and methods of this study while performing a wide variety of complex procedures from all positions around the patient.

Share and Cite:

Kwarcinski, T. , Lichliter, A. , Oros, J. , KC, N. , Yoder, B. and Rees, C. (2020) Occupational Eye Lens Radiation Dose While Performing Interventional Procedures over 18 Months Using a Face-Shield Equipped Suspended Radiation Protection System. Open Journal of Radiology, 10, 101-114. doi: 10.4236/ojrad.2020.102011.

Copyright © 2025 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.