Performance Analysis of Induced Draft Fan Driven by Steam Turbine for 1000 MW Power Units

Abstract

Boiler fan is the main power consumption device in thermal power units and the induced draft fan accounted for the largest proportion. Reducing the energy consumption rate of induced draft fan is the main path to reduce the power consumption rate of thermal power units. The induce fan driven by small turbine is greatly effective for reducing the power consumption rate and the supply coal consumption rate in large thermal power plant. Take 1000 MW power units for example, the selection of steam source for steam turbine were discussed and economic performance of the unit under different steam source was compared in this paper. The result shows that compared with the motor driven method, there is about 1.6 g/kWh decrease in supply coal consumption rate driven by the fourth stage extraction steam; whereas there is about 2.5 g/kWh decrease in supply coal consumption rate driven by the fifth stage extraction steam.

Share and Cite:

J. Deng, F. Liang, Y. Ding, Z. Yang, G. Xu and J. Liu, "Performance Analysis of Induced Draft Fan Driven by Steam Turbine for 1000 MW Power Units," Energy and Power Engineering, Vol. 5 No. 4B, 2013, pp. 1387-1392. doi: 10.4236/epe.2013.54B263.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] R. Wang and W. Y. Yu, “The Energy-saving Analysis on Induced Fan of Power Plant,” Applied Energy Technology, Vol. 5, 2008, pp. 29-30.
[2] J. H. Wu, “Energy Conservation Reform of Boiler Fans in Power Plant,” Power Demand Side Management, Vol. 10, No. 1, 2008, pp. 42-45.
[3] L. Dong, “Energy Saving Analysis of Boiler Fans in Power Plant,” Compressor, Blower &Fan Technology, Vol. 4, 2008, pp. 57-59.
[4] H. Yuan, “Discussion on the Reduction of the Station Service Power Consumption Rate for 1000 MW Power Generation Unit,” Electric Power Survey & Design, 2010, Vol. 4, pp. 49-51.
[5] Y. F. Gao, “Application of Hydraulic Couplers to Energy Saving for Power Plants,” East China Electric Power, Vol. 9, 2006, pp. 87-89.
[6] G. F. Yue, “Analysis on Benefit after Transmission of Induced Draft Fans are Replaced by Hydraulic Couples,” Fujian Power and Electrical Engineering, Vol. 12, 2000, pp. 30-31.
[7] C. X. Liu, “Application of Inverter on Boiler Wind Fan," Compressor, Blower &Fan Technology, Vol. 4, 2010, pp. 59-60.
[8] G. H. Zhang and H. P. Wang, “Applications of High Voltage Inverter on Boiler Fans in Power Plant,” Coal Science & Technology Magazine, Vol. 1, 2009, pp. 51-52.
[9] P. Zhang, “Discussion on the System of Turbine-Driven Induced Fan of Power Generation Unit,” Applied Energy Technology, Vol. 8, 2010, pp. 17-19.
[10] T. K. Zheng, “Thermal Power Units,” China Electric Power Press, Beijing, 2001, pp. 63-64.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.