Continuously Injection with Diluted Heparin Solution via Catheter for Implantation of Totally Implantable Access Ports (TIAP)

Abstract

Background: Totally implantable access ports (TIAP) could be done in two methods: puncture of subclavian vein and cephalic vein cutdown. Cephalic vein cutdown method has fewer complications but has higher failure rates. We present a method to decrease the failure rates. Methods: We use the continuously injection with diluted heparin solution via catheter while introducing the TIAP catheter into the cephalic vein. Results: From January 2005 to January 2009, 20 patients were performed. This method was successfully applied in 11 patients with no complications. The other 9 patients was unsuccessfully and further underwent guidewire assisted. Conclusions: Continuously injection with diluted heparin solution via catheter while inserting TIAP catheter into the cephalic vein is safe and simple. It could be used for difficulties of insertion of TIAP and increased the successful rates of cephalic vein cut-down method.

Share and Cite:

C. Lin, J. Ou, Y. Lee and H. Wu, "Continuously Injection with Diluted Heparin Solution via Catheter for Implantation of Totally Implantable Access Ports (TIAP)," Surgical Science, Vol. 3 No. 7, 2012, pp. 371-372. doi: 10.4236/ss.2012.37073.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] S. J. Davis, J. S. Thompson and J. A. Edney, “Insertion of Hickman Catheters. A Comparison of Cutdown and Percutaneous Techniques,” The American Surgeon, Vol. 50, No. 12, 1984, pp. 673-676.
[2] S. M. Seiler, B. E. Frohlich, U. J. Dorsam, P. Kienle, M. W. Buchler and H. P. Knaebel, “Surgical Technique for Totally Implantable Access Ports (TIAP) Needs Improvement: A Multivariate Analysis of 400 Patients,” Journal of Surgical Oncology, Vol. 93, No. 1, 2006, pp. 24-29. doi:10.1002/jso.20410
[3] F. C. Au, “The Anatomy of the Cephalic Vein,” The American Surgeon, Vol. 55, No. 10, 1989, pp. 638-639
[4] T. Chuter and P. M. Starker, “Placement of Hickman-Broviac Catheters in the Cephalic Vein,” Surgery, Gynecology & Obstetrics, Vol. 166, No. 2, 1988, pp. 163-164.
[5] H. M. Chang, H. F. Hsieh, S. D. Hsu, G. S. Liao, C. H. Lin, C. B. Hsieh and J. C. Yu, “Guidewire Assisted Cephalic Vein Cutdown for Insertion of Totally Implantable Access Ports,” Journal of Surgical Oncology, Vol. 95, No. 2, 2007, pp. 156-157. doi:10.1002/jso.20584

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.