Introduction: In this paper a simulation model for predicting the temperature during the application of focused ultrasound (FUS) for stroke treatment using pulsed ultrasound is presented. Materials and methods: A single element spherically focused transducer of 5 cm diameter, focusing at 10 cm and operating at either 0.5MHz or 1MHz was considered. The power field was estimated using the Khokhlov-Zabolot-skaya-Kuznetzov (KZK) model. The temperature was estimated using the bioheat equation. The goal was to extract the acoustic parameters (frequency, power, and duty factor) that maintain a temperature increase of less than 1oC during the application of a pulse ultrasound protocol. Results: It was found that the temperature change increases linearly with duty factor. The higher the power, the lower the duty factor needed to keep the temperature change to the safe limit of 1oC. The higher the frequency the lower the duty factor needed to keep the temperature change to the safe limit of 1oC. Finally, the shallow the target, the lower the duty factor needed to keep the temper-ature change to the safe limit of 1oC. The simulation model was tested in brain tissue during the application of pulse ultrasound and the measured temperature was in close agreement with the simulated tem-perature. Conclusions: This simulation model is con-sidered to be very useful tool for providing acoustic parameters (frequency, power, and duty factor) dur-ing the application of pulsed ultrasound at various depths in tissue so that a safe temperature is main-tained during the treatment. This model will be tested eventually during stroke clinical trials.

Share and Cite:

Hadjisavvas, V. and Damianou, C. (2011) Temperature estimation of focused ultrasound exposures for stroke treatment. Journal of Biomedical Science and Engineering, 4, 410-417. doi: 10.4236/jbise.2011.45052.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Alexandrov, A.V., Molina, C.A., Grotta, J.C. et al. (2004) Ultrasoundenhanced systemic thrombolysis for acute ischemic stroke. New England Journal of Medicine, 351, 2170-2178. doi:10.1056/NEJMoa041175
[2] Maxwell, A.D., Owens, G., Gurm, H.S., Ives, K., Myers Jr, D.D. and Xu, Z. (2010) Noninvasive treatment of deep venous thrombosis using pulsed ultrasound cavitation therapy (histotripsy) in a porcine model. Journal of Vascular Interventional Radiology, 22, 369-377. doi:10.1016/j.jvir.2010.10.007
[3] Maxwell, A.D., Cain, C.A., Duryea, A.P., Yuan, L., Gurm, H.S. and Xu, Z. (2009) Noninvasive thrombolysis using pulsed ultrasound cavitation therapy-histotripsy. Ultrasound in Medicine and Biology, 35, 1982-1994. doi:10.1016/j.ultrasmedbio.2009.07.001
[4] Spengos, K., Behrens, S., Daffertshofer, M., Dempfle, C.E. and Hennerici, M. (2000) Acceleration of thrombolysis with ultrasound through the cranium in a flow model. Ultrasound in Medicine and Biology, 26, 889- 895.
[5] Eggers, J., Konig, I.R., Koch, B., Handler, G. and Seidel, G. (2008) Sonothrombolysis with transcranial color- coded sonography and recombinant tissue-type plasminogen activator in acute middle cerebral artery main stem occlusion: Results from a randomized study. Stroke, 39, 1470-1475. doi:10.1161/STROKEAHA.107.503870
[6] Clement, G.T. (2004) Perspectives in clinical uses of high-intensity focused ultrasound. Ultrasonics, 42, 1087- 1093. doi:10.1016/j.ultras.2004.04.003
[7] Li, C.-X., Xu, G.-L., Jiang, Z.-Y., Li, J.-J., Luo, G.-Y., Shan, H.-B., Zhang, R. and Li, Y. (2004) Analysis of clinical effect of high-intensity focused ultrasound on liver cancer. World Journal of Gastroenterol, 10, 2201-2204.
[8] Damianou, C., Ioannides, K., Hadjisavvas, V., Milonas, N., Couppis, A. and Iosif, D. (2009) In vitro and in vivo brain ablation created by high intensity focused ultrasound and monitored by MRI. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 56, 1189-1198. doi:10.1109/TUFFC.2009.1160
[9] Kennedy, J.E. (2005) High-intensity focused ultrasound in treatment of solid tumors. Nature Reviews Cancer, 5, 321-327. doi:10.1038/nrc1591
[10] Zenitani, T., Suzuki, R., Maruyama, K. and Furuhata, H. (2008) Accelerating effects of ultrasonic thrombolysis with bubble liposomes. Journal of Medical Ultrasonics, 35, 5-10. doi:10.1007/s10396-007-0163-x
[11] Soltani, A., Prokop, A. and Vaezy, S. (2008) Stability of alteplase in presence of cavitation. Ultrasonics, 48, 109-116. doi:10.1016/j.ultras.2007.10.003
[12] Eggers, J., Ossadnik, S. and Seidel, G. (2009) Enhanced clot dissolution in vitro by 1.8-mhz pulsed ultrasound. Ultrasound in Medicine and Biology, 35, 523-526. doi:10.1016/j.ultrasmedbio.2008.09.009
[13] Shaw, G., Meunier, J., Lindsell, C. and Holland, C. (2008) Tissue plasminogen activator concentration dependence of 120 khz ultrasound-enhanced thrombolysis. Ultrasound in Medicine and Biology, 34, 1783-1792. doi:10.1016/j.ultrasmedbio.2008.03.020
[14] Saguchi, T., Onoue, H., Urashima, M., Ishibashi, T., Abe, T. and Furuhata, H. (2008) Effective and safe conditions of low-frequency transcranial ultrasonic thrombolysis for acute ischemic stroke: Neurologic and histologic evaluation in a rat middle cerebral artery stroke model. Stoke, 39, 1007-1011.
[15] Eggers, J., K?nig, I.R., Koch, B., H?ndler, G. and Seidel, G. (2008) Sonothrombolysis with transcranial color-coded sonography and recombinant tissue-type plasminogen activator in acute middle cerebral artery main stem occlusion: Results from a randomized study. Stroke, 39; 1470-1475. doi:10.1161/STROKEAHA.107.503870
[16] Kim, Y.S., Rhim, H., Choi, M.J., Lim, H.K. and Choi, D. (2008) High-intensity focused ultrasound therapy: an overview for radiologists. Korean Journal of Radiology, 9, 291-302.
[17] Stone, M.J., Frenkel, V., Dromi, S., Thomas, P., Lewis, R.P., Li, K.C., Horne 3rd, M. and Wood, B.J. (2007) Pulsed-high intensity focused ultrasound enhanced tPA mediated thrombolysis in a novel in vivo clot model, a pilot study. Thrombosis Research, 121, 193-202. doi:10.1016/j.thromres.2007.03.023
[18] Frenkel, V., Oberoi, J., Stone, M.J., Park, M., Deng, C., Wood, B.J., Neeman, Z., Horne 3rd, M. and Li, K.C. (2006) Pulsed high-intensity focused ultrasound enhances thrombolysis in an in vitro model. Radiology, 239, 86-93.
[19] Sapareto, S. and Dewey, W. (1984) Thermal dose determination in cancer therapy. International Journal of Radiation Oncology Biology Physics, 10, 787-800. doi:10.1016/0360-3016(84)90379-1
[20] Soneson, J.E. and Myers, M.R. (2007) Gaussian representation of high-intensity focused ultrasound beams. Journal of the Acoustical Society of America, 122, 2526-2531.
[21] Pennes, M. (1948) Analysis of tissue and arterial blood temperature in the resting human forearm. Journal of Applied Physiology, 1, 93-122.
[22] Holland, C.K., Vaidya, S.S., Datta, S., Coussios, C.-C. and Shaw, G.J. (2007) Ultrasoundenhanced tissue plasminogen activator thrombolysis in an in vitro porcine clot model. Thrombosis Research, 121, 663-673.
[23] Kornowski, R., Meltzer, R.S., Chernine, A., Vered, Z. and Battler, A. (1994) Does external ultrasound accelerate thrombolysis? Results from a rabbit model. American Heart Association, 89, 339-344.
[24] Nedelmann, M., Reuter, P., Walberer, M., Sommer, C., Alessandri, B., Schiel, D., Ritschel, N., Kempski, O., Kaps, M., Mueller, C., Bachmann, G. and Gerriets, T. (2008) Detrimental effects of 60 Khz Sonothrombolysis in rats with middle cerebral artery occlusion. Ultrasound in Medicine and Biology, 34, 2019-2027. doi:10.1016/j.ultrasmedbio.2008.06.003
[25] Hynynen, K., Darkazanli, A., Unger, E. and Schenck, J. (1993) MRI-guided non-invasive ultrasound surgery. Medical Physics, 20, 107-115. doi:10.1118/1.597093
[26] Ishibashi, T., Akiyama, M., Onoue, H., Abe, T. and Furuhata, H. (2002) Can transcranial ultrasonication increase recanalization flow with tissue plasminogen activator? Stroke, 33, 1399-1404. doi:10.1161/01.STR.0000013789.15436.42

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.