Some Reasons to Revise the International Standard ISO 226:2003: Acoustics—Normal Equal-Loudness-Level Contours
Juhani Parmanen
Espoo, Finland.
DOI: 10.4236/oja.2012.24016   PDF    HTML     5,813 Downloads   12,781 Views   Citations

Abstract

The recent Standard ISO 226 concerning equal-loudness-level contours has been critically analysed. As a result, it is shown that the fitting and smoothing processes applied in the standard lead to parameter values defining equal-loudness-level contours that are not consistent with the chosen loudness function type. Serious mathematical and acoustical discrepancies have also been found that result in constant terms having an unnecessarily high numerical accuracy and a flawed phon definition, which leads to an erroneous loudness level representation. Therefore an extensive treatment of the logarithmic calculations (phon) of a loudness function is performed in this study. Finally, the author concludes that it would be desirable for the discrepancies in the standard (shown in the study) to be taken into account and corrected before publishing a new version of the standard.

Share and Cite:

J. Parmanen, "Some Reasons to Revise the International Standard ISO 226:2003: Acoustics—Normal Equal-Loudness-Level Contours," Open Journal of Acoustics, Vol. 2 No. 4, 2012, pp. 143-149. doi: 10.4236/oja.2012.24016.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] International Standardization Organization, “ISO 226: 2003(E): Acoustics—Normal Equal-Loudness-Level Contours,” Geneva, Switzerland.
[2] J. Parmanen, “A-Weighted Sound Pressure Level as a Loudness/Annoyance Indicator for Environmental Sounds— Could It Be Improved?” Applied Acoustics, Vol. 68, No. 1, 2007, pp. 58-70. doi:10.1016/j.apacoust.2006.02.004
[3] J. Parmanen, “Erratum: A-Weighted Sound Pressure Level as a Loudness/Annoyance Indicator for Environmental Sounds—Could It Be Improved? [Applied Acoustics, 68 (2007) 58-70],” Applied Acoustics, Vol. 69, No. 2, 2008, p. 183. doi:10.1016/j.apacoust.2006.09.006
[4] Y. Suzuki and H. Takeshima, “Equal-Loudness-Level Contours for Pure Tones,” Journal of the Acoustical Society of America, Vol. 116, No. 2, 2004, pp. 918-933. doi:10.1121/1.1763601
[5] International Standardization Or-ganization, “ISO 226:1987 (E): Acoustics—Normal Equal-Loudness-Level Contours,” Geneva, Switzer-land.
[6] International Standardization Organization, “ISO 532:1975 (E): Acoustics—Method For Calculating Loudness Level,” Geneva, Switzerland.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.