Tele-care for emergency announcements
Ching-Sung Wang, Chien-Wei Liu, Teng-Wei Wang
.
DOI: 10.4236/jbise.2010.38110   PDF    HTML     4,606 Downloads   8,269 Views   Citations

Abstract

The first aid and immediately help are very important in an accident. The earlier detection and treatment we do, the better prognosis and health patients have. In the senior populations, it is more important. Once seniors have an accident, not only physically injure in their body, but also mental and social ability, and may have severe sequela. Concerning about these populations, this research design a simple, practical, and portable device of real-time monitoring body activity with sphygmomanometer and pulsimeter. When an accident occurs, the signals go through mobile phone, immediately notify the remote ends and provide first time help.

Share and Cite:

Wang, C. , Liu, C. and Wang, T. (2010) Tele-care for emergency announcements. Journal of Biomedical Science and Engineering, 3, 822-827. doi: 10.4236/jbise.2010.38110.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Cummins, R.O., Eisenberg, M.S., Hallstrom, A.P. and Litwin, P.E. (1985) Survival of out-of-hospital cardiac arrest with early initiation of cardiopulmonary resuscitation. American Journal of Emergency Medicine, 3(2), 114-119.
[2] Albarede, J.L., Lemieux, A., Vellas, B. and Groulx, B. (1989) Psychological factors in falls in elderly patients. Canadian Journal of Psychiatry, 34(2), 94-96.
[3] Maki, B.E., Holliday, P.J. and Topper, A.K. (1991) Fear of falling and postural performance in the elderly. Journal of Gerontology, 46(4), 123-131.
[4] Wang, C.S., Lee, J.H. and Chu, Y.T., (2007) Mobile telemedicine application and technologies on GSM. Bioinformatics and Biomedical Engineering, ICBBE, the 1st International Conference, 6-8 July 2007, 1125-1128.
[5] Bluetooth Special Interest Group (2005) Bluetooth Specification, Hands-Free Profile (HFP) 1.5, November 25.
[6] Bluetooth Special Interest Group (2001) Bluetooth spe- cification. Serial Port Profil, 1.1, February 22.
[7] National Semiconductor Inc. (2005) SC14440/431/432, SC14435, SC14436/437/438. Baseband Processor for PP/FP DECT and WDCT, 1.1, June 16.
[8] MEMSIC Inc. (2007) MXA2500G/M Improved, Ultra Low Noise ±1.7 g Dual Axis Accelerometer with Absolute Outputs, Rev. G, June.
[9] CSR Inc. (2006) BlueCore3-ROM CSP Product Data Book, November.
[10] SiRF Inc. (2003) SiRF starIIe/LP Chip Set Data Sheet, Rev 1.1, February.
[11] Nissila, S., Sorvisto, M., Sorvoja, H., Vieri-Gashi, E. and Myllyla, R. (1998) Non-invasive blood pressure measurement based on the electronic palpation method. Engineering in Medicine and Biology Society, Proceedings of the 20th Annual International Conference of the IEEE, 4, 1723-1726.
[12] Y.-B. Lin and I. Chlamtac, (2000) Wireless and mobile network architectures. Wiley Computer Publishing, New Delhi.
[13] Wang, C.-S. (2010) Mobile and wireless technologies applying on sphygmomanometer and pulsimeter for patients with pacemaker implementation and other cardiovascular complications. Journal of Biomedical Science and Engineering, 3(1), 47-51.
[14] HoneyWell, (2002) SSC Series Pressure Sensors 0-5 psi Through 0-300 psi.
[15] Winbond Inc., (2006) W681388 Single Programmable Extended CODEC/SLIC, Ver. 1.0.
[16] Micrpchip Inc., (2007) PIC24FJ64GA004 Family Data Sheet.
[17] Bluetooth Special Interest Group (2004) Specification of the Bluetooth System Core, Ver., 2.0.
[18] Pravin Bhagwat Reefedge Inc., (2001) Bluetooth: Technology for short-range wireless apps, IEEE Internet Computing, 5, 96-103.
[19] MEMSIC Inc., (2005) Body Activity Detection Reference Design, August 25.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.