World Journal of Cardiovascular Surgery

Volume 4, Issue 7 (July 2014)

ISSN Print: 2164-3202   ISSN Online: 2164-3210

Google-based Impact Factor: 0.10  Citations  

Correlation of Electric Cardiometry and Continuous Thermodilution Cardiac Output Monitoring Systems

HTML  XML Download Download as PDF (Size: 1045KB)  PP. 101-108  
DOI: 10.4236/wjcs.2014.47016    4,100 Downloads   6,502 Views  Citations

ABSTRACT

Purpose: Impedance Cardiography (ICG) with its drawbacks to reliably estimate cardiac output (CO) when compared to reference methods has led to the development of a novel technique called Electrical Cardiometry (EC). The purpose of this study was to compare EC-CO with the Continuous CO (CCO) derived from Pulmonary Artery Catheter (PAC). Methods: 60 patients scheduled to undergo coronary artery surgery necessitating the placement of PAC were studied in the operating room. Standard ECG electrodes were used for EC-CO measurements. Simultaneous CO measurement from EC and PAC was done at three predefined time points and were correlated. Results: A significant high correlation was found between the EC-CO and CCO at the three time points. Bland and Altman analysis revealed a bias of 0.08 L/min, a precision of 0.15 L/min, with a narrow limit of agreement (-0.13 to 0.28 L/min). The percentage error between the methods was 3.59%. Conclusion: The agreement between EC-CO and CCO is clinically acceptable and these two techniques can be used interchangeably. Mediastinal opening has no effect on the correlation between these two modalities.

Share and Cite:

Malik, V. , Subramanian, A. , Chauhan, S. and Hote, M. (2014) Correlation of Electric Cardiometry and Continuous Thermodilution Cardiac Output Monitoring Systems. World Journal of Cardiovascular Surgery, 4, 101-108. doi: 10.4236/wjcs.2014.47016.

Cited by

[1] Electrocardiometry for Hemodynamic Categorization and Assessment of Fluid Responsiveness in Pediatric Septic Shock: A Pilot Observational Study
2021
[2] Electrocardiometry Fluid Responsiveness in Pediatric Septic Shock.
2021
[3] Adaptation à l'effort des patients avec une sténose aortique avant et après l'implantation d'une valve aortique par voie transartérielle (TAVI): aspects hémodynamique …
2021
[4] Electrocardiometry Fluid Responsiveness in Pediatric Septic Shock
Indian Journal of Critical Care Medicine: Peer …, 2021
[5] Vpliv Infuzije Efedrina in Feniefrina Na Stabilnost obtočil Po Subarahnoidni Anesteziji Pri starejših Bolnikih
2020
[6] The accuracy of electrical cardiometry for the noninvasive determination of cardiac output before and after lung surgeries compared to transthoracic …
2020
[7] The influence of the infusion of ephedrine and phenylephrine on the hemodynamic stability after subarachnoid anesthesia in senior adults-a controlled …
2019
[8] 休克患者的血流动力学监测现状与展望
2019
[9] Analisis Profil Syok Berdasarkan Ekokardiografi Terfokus Pada Satu Jam dan Tiga Jam Pertama Resusitasi Kasus Pediatri Dengan Syok Septik
2019
[10] Comparison of del Nido and histidine-tryptophan-ketoglutarate cardioplegia solutions in pediatric patients undergoing open heart surgery: A prospective randomized …
2019
[11] Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis
2019
[12] Predictive and prognostic roles of electrical cardiometry in noninvasive assessments of community-acquired pneumonia patients with dyspnoea
2019
[13] ICON 无创心输出量监测在感染性休克患者中的准确性研究
2018
[14] Effect of administration of allopurinol on postoperative outcomes in patients undergoing intracardiac repair of tetralogy of Fallot
2018
[15] Cardiac function measurements by electrical cardiometry in 24-hour ultra-marathoners
2018
[16] Oral thyroxin supplementation in infants undergoing cardiac surgery: A double-blind placebo-controlled randomized clinical trial
The Journal of Thoracic and Cardiovascular Surgery, 2018
[17] Comparison of del Nido and St Thomas cardioplegia solutions in pediatric patients: A prospective randomized clinical trial
2017
[18] Continuous infusion of furosemide versus intermittent boluses in acute decompensated heart failure: Effect on thoracic fluid content
The Egyptian Heart Journal, 2017
[19] 无创心指数检测在评价新生儿先天性心脏病 合并心力衰竭的临床应用价值# br
2017
[20] Monitoring of heart pumping function in healthy volunteers using impedance plethysmography
2017
[21] 无创心指数检测在评价新生儿先天性心脏病合并心力衰竭的临床应用价值
2017
[22] Impedanzkardiographie: Evaluation als nichtinvasives Trendmonitoring bei hämodialysierten Kindern
2016
[23] Continuous non-invasive cardiac output monitoring during exercise: validation of electrical cardiometry with Fick and thermodilution methods
British Journal of Anaesthesia, 2016
[24] Non invasive adjustment of fluid status in critically ill patients on renal replacement therapy. Role of Electrical Cardiometry
The Egyptian Journal of Critical Care Medicine, 2016
[25] Prediction of future overt pulmonary hypertension by 6-min walk stress echocardiography in patients with connective tissue disease
Journal of the American College of Cardiology, 2015

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.