International Journal of Medical Physics, Clinical Engineering and Radiation Oncology

Vol.7 No.1(2018), Paper ID 82561, 13 pages

DOI:10.4236/ijmpcero.2018.71007

 

Comparison of Gamma Pass Rate between the Dose-to-Water and Dose-to-Medium Reporting Modes for Patient-Specific QA Using a Helical Diode Array Dosimeter with a Fixed Phantom Density

 

Hideaki Hirashima, Mitsuhiro Nakamura, Yoshitomo Ishihara, Nobutaka Mukumoto, Mami Akimoto, Tsuneyuki Tomita, Yoshinori Hirose, Kenji Kitsuda, Takashi Ishigaki, Takashi Mizowaki

 

Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
Department of Information Technology and Medical Engineering, Faculty of Human Health Science, Graduate School of Medicine, Kyoto University, Kyoto, Japan
Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
Division of Radiology, Osaka Red Cross Hospital, Osaka, Japan
Division of Radiology, Osaka Red Cross Hospital, Osaka, Japan
Division of Radiology, Osaka Red Cross Hospital, Osaka, Japan
Department of Radiation Therapy, Osaka Red Cross Hospital, Osaka, Japan
Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan

 

Copyright © 2018 Hideaki Hirashima, Mitsuhiro Nakamura, Yoshitomo Ishihara, Nobutaka Mukumoto, Mami Akimoto, Tsuneyuki Tomita, Yoshinori Hirose, Kenji Kitsuda, Takashi Ishigaki, Takashi Mizowaki et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

 

How to Cite this Article


Hirashima, H. , Nakamura, M. , Ishihara, Y. , Mukumoto, N. , Akimoto, M. , Tomita, T. , Hirose, Y. , Kitsuda, K. , Ishigaki, T. and Mizowaki, T. (2018) Comparison of Gamma Pass Rate between the Dose-to-Water and Dose-to-Medium Reporting Modes for Patient-Specific QA Using a Helical Diode Array Dosimeter with a Fixed Phantom Density. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 7, 74-86. doi: 10.4236/ijmpcero.2018.71007.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.