International Journal of Medical Physics, Clinical Engineering and Radiation Oncology

Vol.3 No.1(2014), Paper ID 42558, 8 pages

DOI:10.4236/ijmpcero.2014.31001

 

Spine Stereotactic Body Radiation Therapy Residual Setup Errors and Intra-Fraction Motion Using the Stereotactic X-Ray Image Guidance Verification System

 

Kosj Yamoah, Nicholas G. Zaorsky, Joshua Siglin, Wenyin Shi, Maria Werner-Wasik, David W. Andrews, Adam P. Dicker, Voichita Bar-Ad, Haisong Liu

 

Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center of Thomas Jefferson University, Philadelphia, USA
Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center of Thomas Jefferson University, Philadelphia, USA; Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, USA
Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center of Thomas Jefferson University, Philadelphia, USA
Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center of Thomas Jefferson University, Philadelphia, USA
Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center of Thomas Jefferson University, Philadelphia, USA
Department of Neurological Surgery, Jefferson Medical College, Philadelphia, USA
Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center of Thomas Jefferson University, Philadelphia, USA
Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center of Thomas Jefferson University, Philadelphia, USA
Department of Radiation Oncology, Jefferson Medical College and Kimmel Cancer Center of Thomas Jefferson University, Philadelphia, USA

 

Copyright © 2014 Kosj Yamoah, Nicholas G. Zaorsky, Joshua Siglin, Wenyin Shi, Maria Werner-Wasik, David W. Andrews, Adam P. Dicker, Voichita Bar-Ad, Haisong Liu et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

 

How to Cite this Article


K. Yamoah, N. Zaorsky, J. Siglin, W. Shi, M. Werner-Wasik, D. Andrews, A. Dicker, V. Bar-Ad and H. Liu, "Spine Stereotactic Body Radiation Therapy Residual Setup Errors and Intra-Fraction Motion Using the Stereotactic X-Ray Image Guidance Verification System," International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, Vol. 3 No. 1, 2014, pp. 1-8. doi: 10.4236/ijmpcero.2014.31001.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.