American Journal of Analytical Chemistry
Vol.5 No.2(2014), Article ID:42544,6 pages DOI:10.4236/ajac.2014.52015

Polyvinylbenzyl Tris-Aminodicarboxylate Microspheres for the Optical Sensing of Cu2+ Ions

Ziad M. Shakhsher1, Ibrahim Abu Shqair2, Hanin R. Qasim2, Imad Odeh1*

1Department of Chemistry and Chemical Technology, Al-Quds University, Jerusalem, Palestine

2Department of Chemistry, An-Najah National University, Nablus, Palestine

Email: *odehim@science.alquds.edu

Received November 30, 2013; revised December 29, 2013; accepted January 8, 2014

ABSTRACT

In this work, a tris(2-aminoethyl)aminodicaboxylate functionality was substituted for the chloride of polyvinylbenzyl chloride (PVBC) which was lightly cross-linked (2%) with divinyl benzene. The resulting derivatized polymer microspheres were embedded in a hydrogel matrix of poly vinyl alcohol cross-linked with glutaraldehyde to produce a sensing membrane. The latter responded selectively to Cu2+ solutions of different concentration ranges (1 × 10−4 M to 1 × 10−6 M). The response is based on the interaction between the metal cations and the negatively charged deprotonated dicarboxylate functional group, which led to neutralization of the charges. As a result, an increase in the turbidity of the sensing membrane occurred which is attributed to a change in the refractive index of the derivatized polymer microspheres relative to that of the hydrogel. The change in the turbidity of the sensing membrane was measured as absorbance using a conventional spectrophotometer. It was found that Cu2+ ions bind to the aminodicarboxylated-polymer with a formation constant, Kf, of 1 × 105 M−1. SEM, Eds and IR analyses were performed on the aminodicarboxylated microspheres and their Cu2+ complex.

Keywords:Tris(2-aminoethyl)aminodicarboxylate-Polymer; Optical Sensing; Refractive Index; SEM; Eds

1. Introduction

Heavy metal ions such as Mercury, Cadmium, Lead, Nickel and Copper discharged into water by natural and anthropogenic sources are causing environmental and biological problems and have become a global concern [1-3]. Although a variety of methods are available for their removal, fast and effective means for their detection are still needed [4-17]. In a recent study, selective determination of copper ions in aqueous solutions utilizing aminodicarboxylic acid for the chelation of copper (II) ions was reported. Lin et al. modified the surface of an evanescent wave element by depositing a thin layer of the ligand producing a sensitive and selective infra-red chemical sensor capable of detecting micro molar concentrations of Cu2+ ions within a time frame of 20 minutes [4]. We believe that using an optical chemical sensor would improve significantly the detection limit and produce a faster response time. A variety of analytes were detected using optical sensing elements developed by our group [11-14]. Such a sensor is based on polymer swellings that result from complexation of a specific analyte with a specific functional group located on the polymer microspheres. The latter form a sensing element upon entrapping them in polyvinyl alcohol cross-linked with glutaraldehyde. The resulting sensing element demonstrated excellent resistance to photodegradation and indicator dye leaching as well as to mechanical degradation. In addition, these sensors were effective at very low concentration (down to 1 µM) and responded within a very short time (95% response in 5 minutes) and were insensitive to pH changes [11,14].

In a previous work, we were able to develop an optical chemical sensing element based on polymer swelling, in which polyvinylbenzyl chloride (PVBC) lightly crosslinked with divinylbenzene as microspheres were derivatized with dicarboxylate and embedded in a hydrogel membrane to form a sensing element [12,13]. This kind of sensing element had some limitations, particularly its lack of selectivity. It responded to varying pH values, and also to Ca2+, Ni2+, Zn2+, and Cd2+ ions. To improve the selectivity, we selected a functionality that is chemically similar to that of ethylenediamine tetraacetic acid (EDTA), a common chelating agent for metal ions but known to form highly thermodynamic chelates with Cu2+ ions [4]. In this study, polyvinylbenzyl tris(2-aminoethyl)aminodicarboxylate microspheres were synthesized starting from PVBC cross-linked with divinylbenzene (2%). The resulting derivatized microspheres were embedded in a hydrogel matrix of polyvinylalcohol crosslinked with glutaraldehyde to form an optical sensing element. The response to Cu2+ ions as change in the turbidity of the sensing membrane was measured as absorbance using a conventional spectrophotometer.

2. Experimental

2.1. Reagents

All chemical reagents used were of analytical grade. N,N-dimethylformamide(DMF), tris(2-aminoethyl)amine (TAA), polyvinyl alcohol(PVA), glutaraldehyde 8% by weight, were purchased from Sigma-Aldrich. Bromooacetic acid was obtained from Riedel. All solutions were prepared in deionized distilled water. Polyvinylbenzyl chloride (PVBC) lightly cross-linked with divinylbenzene (2% mole) microspheres of 1 - 3 µM diameter were supplied by the Chemistry Department at the University of New Hampshire (USA).

2.2. Instruments

Absorption measurements were performed on Shimadzu UV-VIS-NIR Scanning spectrophotometer (Shimadzu UV-3101PC). A Fourier transform infrared spectrophotometer (Testscan Shimadzu FT-IR 8000 series) was used to obtain IR-Spectra. The pH measurements were recorded on a Jenway pH meter (3510). SEM and Eds analyses of the adsorbent before and after complexation with copper (II) ions were performed by mounting the samples on metal stubs and coating them with gold (Polaron Spatter coater). The microphotographs were recorded using a scanning electron microscope JEOL model, JSM-5410 LV (available at the microscopy lab at the faculty of agriculture, food and environmental quality Sciences, The Hebrew University). The images were taken with an accelerating voltage of 25 kV, at high vacuum (HV mode) and secondary electron image (SEI). The analysis was done using Oxford systems—Liquid Nitrogen cooled solid state Energy Dispersive Spectrometer detector and link ISIS software.

2.3. Synthesis of the Tris(2-aminoethyl)amino (TAA) Polymer

One gram (0.0066 mole) of PVBC was stirred in 12 ml DMF for two hours then 4 ml of the tris-amine (TAA, 4 equivalents) were added and the reaction was stirred for one week. The DMF and excess tris-amine were then removed by a series of centrifugations, and decantations. Then the polymer was washed several times (3 times) with distilled water. The water was also removed by a series of centrifugations, and decantations. The polymer was allowed to dry in air. The mass of tris-amine polymer obtained was 1.384 g.

2.4. Synthesis of the Tris(2-aminoethyl)aminodicarboxylate (TAAD) Polymer

One gram of the tris-amino polymer was added to a solution of 2 g of Bromoacetic acid in 25 ml 3 M NaOH and the reaction was allowed to stir at room temperature for one week. The reaction was then stopped and the polymer collected by suction filtration. The mass of the polymer obtained was 1.160 g.

2.5. Preparation of the Optical Sensing System

The TAAD derivatized polymer microspheres (10 mg) were soaked in a few drops of DMF for a few minutes, then 1 ml of 5% aqueous PVA solution was added and the mixture was placed in a sonicator until the polymer microspheres were dispersed and the mixture became uniform. Then, the PVA/TAAD mixture was crosslinked by mixing with 80 µl of 8% aqueous glutaraldehyde, followed by 80 µl of 3 M HCl (aq). A few drops of the resulting mixture were immediately transferred and spread on the inner clear side wall of a plastic cuvette. The sensing membrane was allowed to formulate and stick in position. The resulting sensing element was washed with and stored in distilled water. The cuvette with the sensing element stuck on its inner sidewall was secured in the cell holder of a conventional spectrophotometer, so that the membrane was positioned in the path of the light beam (Figure 1).

Figure 1. Diagram of optical sensing system.

2.6. Optical Measurements

The solution in the cuvette was changed using a disposable pipette, starting with the lower concentrations of analyte and proceeding to the higher ones. The change in turbidity of the sensing element as a function of analyte concentration was measured as absorbance at 800 nm. The response of the sensing element to pH was obtained starting with lower pH and proceeding to the higher ones with an interval of 10 minutes between each spectrum run. The reproducibility of the sensor response was evaluated by cycling between blank and 0.001 M Cu2+ ions solution several times. Between measurements, the sensing element was eluted by a saturated solution of EDTA and then washed extensively with distilled water until obtaining the blank reading. The response time of the sensing element towards 0.001 M of Cu2+ ions was obtained by measuring the change in absorbance with time, until steady state is reached.

3. Results and Discussion

3.1. Characterization of the Ligand-Cu2+ Complex

The variation in the appearance of the IR specta of the tris(2-aminoethyl)aminodicaboxylate polymer-Cu2+ complex from that of the tris(2-aminoethyl)aminodicaboxylate polymer is indicative of the complex formation. Thus, the carboxylate characteristic bands for the asymmetric and symmetric stretching frequencies appearing at ca. 1594 and 1438 became less intense [4]. Also two new bands are observed at ca. 1063 and 532 cm−1 which are attributed to the C-O and N-Cu stretching frequencies [18] (Figure 2). SEM analysis showed an increase in the average size of the polymer microspheres possibly due to adsorption of copper ions on the polymer surface in addition to chelation with the aminodicarboxylate functionality (Figure 3). Elemental analysis of the surface of the polymer at three different points using Energy Dispersive Spectrometry (EDS) showed beyond doubt the presence of nitrogen, oxygen and copper, the three-element component of the aminodicarboxylate functionality (Table 1).

3.2. Sensing Element Evaluation

As the sensing element was examined with different buffer solutions (pH 5 - 12), insignificant changes in absorbance were observed. This is probably related to the fact that the tris-aminodicaboxylate polymer contains both basic amino groups and acidic carboxyl groups. The nitrogen and the oxygen are both protonated at low pH. Thus, the positive charges on nitrogen repel each other causing the polymer to be in a swollen state. As the pH is raised, the oxygen on the carboxylic group becomes de-

Figure 2. FTIR spectra: (A) Tris amino dicarboxylate (TAAD) polymer; (B) Tris amino carboxylate-Cu2+ complex.

1 2 3 Size distribution of microspheres (µm)

Figure 3. SEM images of (1) Tris(2-aminoethyl)amino (TAA) polymer; (2) Tris(2-aminoethyl)aminodicaboxylate (TAAD) polymer; (3) Tris(2-aminoethyl)aminocaboxylate polymerCu2+ complex and the size distribution of the polymer microspheres.

protonated. The negative charges repel each other causing the polymer to stay in a swollen state. This behavior does not lead to any significant change in refractive index, and thus no detectable change in absorbance was recorded (Figure 4).

The tris-aminodicarboxylate polymer showed no response towards tested heavy metal cations (Co2+, Ni2+

Table 1. Elemental analysis of tris(2-aminoethyl)aminodicaboxylate polymer-Cu2+ complex.

Figure 4. Turbidity absorbance of the sensing element at different pHs.

Hg2+) at all concentrations (Figure 5). On the other hand, it demonstrated a significant affinity towards Cu2+ ions in agreement with previous reports [4] (Figures 6 and 7).

The response of the sensing membrane to Cu2+ ions is based on the interaction between these ions and the aminodicarboxylate functional group situated on the polymer microspheres.

As a result, an increase in the turbidity of the sensing element occurred due to a change in the refractive index of the derivatized polymer microspheres relative to that of the hydrogel. Thus, as the concentration of the Cu2+ solution was varied between 1 × 10−6 M and 1 × 10−4 M an increase in absorbance was observed. The sensing element demonstrated good reproducibility in response towards Cu2+ ions.

The formation constant (Kf) of binding of Cu2+ ions with the tris-aminodicarboxylate-polymer was obtained

Figure 5. Turbidity absorbance of sensing element vs concentration of Co2+, Ni2+ and Hg2+ ions.

Figure 6. Variation of absorbance of sensing element vs wavelength of different Cu2+ concentration (1 × 10−6 to 1 × 10−4).

Figure 7. Turbidity absorbance of sensing element vs concentration of Cu2+ ions.

from the plot of Figure 7. As the amounts of the free and the bonded ligand will be equal at the point half-way to the maximum response, Kf is equal to 1/[Cu2+], where the concentration of Cu2+ ion is 1 × 10−5 M. Thus, the formation constant (Kf) is calculated to be 1 × 105 M−1. This result ensures the high selectivity of the prepared sensing element toward Cu2+ ion.

The response of the sensing element was examined towards Cu2+ (0.001 M), at different pH buffered solutions (pH 2 - 9). We detected a small change in absorbance up to about pH 7. But, above that, significant increases in absorbance were observed. This is probably due to an increase in the fraction of the deprotonated functional groups that resulted in an enhancement of the complex formation between ligand and Cu2+ ions (Figure 8).

The response time of the sensing membrane toward Cu2+ ions was obtained by measuring the change in absorbance of a solution of 1 × 10−3 M Cu2+ ions at 800 nm versus time. The absorbance increased sharply up to about 5 minutes and then leveled off (Figure 9). This pattern in the response time may be attributed to the increase in the thickness of the shrinking outer layer of the microsphere surface, which resulted in a significant reduction in the rate of diffusion of Cu2+ ions and water through it.

In agreement with previously reported results, the trisaminodicarboxylate polymer microspheres showed no response toward alkali and alkaline earth metal cations, such as Ca2+, Mg2+, K+, and Na+.

Thus, the presence of these metal cations will not be expected to affect the optical properties of the sensing membrane (Figure 10).

4. Conclusion

In this work, a tris-aminodicarboxylate functional group was substituted for the chloride of PVBC which was cross-linked with divinyl benzene (2%). The resulting derivatized microspheres were entrapped in a hydrogel membrane (PVA) to produce a sensing element. The resulting sensor responded selectively to Cu2+ ions at concentrations ranging between 1 × 10−6 M and 1 × 10−4 M,

Figure 8. Turbidity absorbance of the sensing element for 0.001 M Cu2+ at different pHs.

Figure 9. Response time of the sensing element towards Cu2+ ions.

Figure 10. Turbidity absorbance of sensing element vs concentration of alkali and alkaline earth metal ions.

with a formation constant (Kf) of 1 × 105 M−1. In addition, no significant response to other metal ions, especially alkali and alkaline earth metal and some heavy metal ions (Co2+, Ni2+, Hg2+) was detected, regardless of their concentrations.

Acknowledgements

We are grateful to Professor W. R. Seitz and his research group, at the University of New Hampshire (USA) for their fruitful comments and for supplying us with the polyvinylbenzyl chloride microspheres. We are also grateful to the staff at the department of chemistry of An-Najah National University (PA), for their technical assistance.

REFERENCES

  1. J. Moore, “Inorganic Contaminants of Surface Water,” Springer-Verlag, New York, 1991. http://dx.doi.org/10.1007/978-1-4612-3004-5

  2. B. Carson, H. Ellis and J. MacCann, “Toxicology and Biological Monitoring of Metals in Humans,” Lewis Publishers, Chelsea, 1987.

  3. D. Barceloux, “Copper,” Journal of Toxicology-Clinical Toxicology Vol. 37, No. 2, 1999, pp. 217-230. http://dx.doi.org/10.1081/CLT-100102421

  4. H. C. Lin, Y. H. Chou and J. Yang, “Development of an Amino Carboxylic Acid-Modified Infrared Chemical Sensor for Selective Determination of Copper Ions in Aqueous Solutions,” Analytica Chimica Acta, Vol. 611, No. 1, 2008, pp. 89-96. http://dx.doi.org/10.1016/j.aca.2008.01.069

  5. X. Zhang, X. Kong, W. Fan and X. Du, “Iminodiacetic Acid-Functionalized Gold Nanoparticles for Optical Sensing of Myoglobin via Cu2+ Coordination,” Langmuir, Vol. 27, No. 10, 2011, pp. 6504-6510. http://dx.doi.org/10.1021/la200177e

  6. A. Richter, G. Paschew, S. Klatt, J. Leinig, K. F. Arndt and H. J. P. Adler, “Review on Hydrogel-Based pH Sensors and Microsensors,” Sensors, Vol. 8, No. 1, 2008, pp. 561-581. http://dx.doi.org/10.3390/s8010561

  7. P. C. A. Jeronimo, A. N. Araujo, M. Conceicao and B. S. M. Montenegro, “Optical Sensors and Biosensors Based on Sol-Gel Films,” Talanta, Vol. 72, No. 1, 2007, pp. 13- 27. http://dx.doi.org/10.1016/j.talanta.2006.09.029

  8. J. Y. Haras, D. Silvio, R. Rodrigues and M. Negri, “Chelating Electrodes as Taste Sensor for the Trace Assessment of Metal Ions,” Sensors and Actuators, Vol. 145, No. 2, 2010, pp. 726-733. http://dx.doi.org/10.1016/j.snb.2010.01.027

  9. W. R. Seitz, M. T. Rooney, E. W. Miele, H. Wang, N. Kaval, L. Zhang, S. Doherty, S. Milde and J. Lenda, “Derivatized Swellable Polymer Microspheres for Chemical Transduction,” Analytica Chimica Acta, Vol. 400, No. 1-3, 1999, pp. 55-64. http://dx.doi.org/10.1016/S0003-2670(99)00608-X

  10. O. Oktar, P. Caglar and W. R. Seitz, “Chemical Modulation of Themosensitive Poly(N-isopropyl acryamide) Microsphere Swelling: A New Strategy for Chemical Sensing,” Sensors and Actuators B, Vol. 104, No. 2, 2005, pp. 179-185. http://dx.doi.org/10.1016/j.snb.2004.04.033

  11. Z. Shakhasher, I. Odeh, I. Rajabi and M. Khatib, “Optical Sensing Properties of Dithiocarbamate Functionalized Microspheres, Using a Polyvinyl Pyridine-Polyvinyl Benzyl Chloride Copolymer,” Sensors, Vol. 10, No. 10, 2010, pp. 8953-8962. http://dx.doi.org/10.3390/s101008953

  12. Z. Shakhasher, I. Odeh, S. Jabr and W. R. Seitz, “An Optical Chemical Sensor Based on Swellable Dicarboxylate Functionalized Polymer Microspheres for pH Copper and Calcium Determination,” Microchimica Acta, Vol. 144, No. 1-3, 2004, pp. 147-153. http://dx.doi.org/10.1007/s00604-003-0077-2

  13. I. Odeh, Z. Shakhsher, S. Jaber, M. Khatib and F. Rimawi, “An Optical Sensor Based on Polyvinyl Benzyl Malonate Cross-Linked with Divinyl Benzene Dispersed in a Hydrogel Membrane for Detection of Some Heavy Metals,” American Journal of Analytical Chemistry, Vol. 3, No. 4, 2012, pp. 283-287. http://dx.doi.org/10.4236/ajac.2012.34038

  14. I. Odeh, S. Siam, M. Khatib and Z. Shakhasher, “An Optical Chemical Sensor Based on Polymer Swelling and Shrinking Using Dithiocarbamate-Polymer Microspheres,” Jordan Journal of Chemistry, Vol. 4, 2009, pp. 55-64.

  15. K. Liu and H. F. Ji, “Detection of Pb2+ Using a Hydrogel Swelling Micro Cantilever Sensor,” Analytical Sciences, Vol. 20, No. 1, 2004, pp. 9-11. http://dx.doi.org/10.2116/analsci.20.9

  16. J. H. Holtz and S. A. Asher, “Polymerized Colloidal Crystal Hydrogel Films as Intelligent Chemical Sensing Materials,” Nature, Vol. 389, No. 6653, 1997, pp. 829- 832. http://dx.doi.org/10.1038/39834

  17. W. Li, H. Zhao, P. R. Teasdal, R. John and S. Zhang, “Synthesis and Characterization of a PolyacrylamidePolyacrylic Acid Copolymer Hydrogel for Environmental Analysis of Cu and Cd,” Reactive and Functional Polymers, Vol. 52, No. 1, 2002, pp. 31-41. http://dx.doi.org/10.1016/S1381-5148(02)00055-X

  18. M. Sonmez, “Synthesis and Characterization of Copper (II), Nickel (II), Cadmium (II), Cobalt (II), and Zinc (II) Complexes with 2-Benzoyl-3-hydroxy-1-naphthyl Amino-3-phenyl-2-propen-1-on,” Turkish Journal of Chemistry, Vol. 25, 2001, pp. 181-185.

NOTES

*Corresponding author.