1. Introduction
Greatest amount of solar energy is available in two broad bands [1] encircling the earth between 15˚ and 35˚ latitude north and south. The next best position is the equatorial belt between 15˚N and 15˚S latitude [2]. Most of the developing countries, being situated in [3] these regions, are in a favorable position in respect of solar energy. Bangladesh is situated between 20.34˚ and 26.38˚ latitude [4] north and as such has a good solar energy potential. Average daily solar irradiation [5] at flat surface is around 4.0 to 6.5 kWh/m2 in Bangladesh (Figure 1). Solar water heaters are used all over the world [6,7] specifically in sunny countries where sun-shine is abundant. The hot water is used for household purpose and in restaurants, hospitals, dormitories, etc. for cleaning dishes and other works. These heaters are also used for preheating water for industrial purpose. In Bangladesh, solar water heaters are getting popular slowly. There are a few companies who are selling these heaters. Most of the water heaters are of Chinese origin and some are of Indian origin. Unlike Nepal, water heaters are not that popular as gas heaters are cheaper in our country. As the water heaters are installed for 13 months on OAB building so data of 1 year (12 months) have been collected and analyzed. However, the data collected in the winter time contains some useful information.
2. Application of Solar Energy
Most of the solar energy applications [8] are concerned with trapping sunlight as photovoltaic (PV) heat. Because of the low energy density of sunlight, the higher the temperature needed the more complicated and expensive [9] the system will be. Depending on the range of temperature use, solar thermal applications [10] are divided into the three broad categories:
1) Low-temperature applications (below 100˚C), such as solar drying, hot water supplies, cooking.
2) Medium-temperature applications (below 150˚C), such as refrigeration, industrial process heat, etc.
3) High-temperature (above 150˚C) applications, such as electricity generation
3. Solar Water Heater
As In any collection device, the principle usually followed is to expose a dark surface to solar radiation so that the radiation is absorbed. A part of the absorbed radiation is then transferred to a fluid like air or water. When no optical concentration is done, the device in which the collection is achieved is called a flat-plate collector.
The flat-plate collector is the most important type of solar collector because it is simple in design, has no moving parts and requires little maintenance. It can be used for a variety of applications in which temperatures ranging from 40˚C to about 100˚C are required.
4. Thermosyphone
The principle of thermosyphone [11] is just like boiling the water. In a flat bed collector cold water flows to the collector, it gets warm by sunshine and flows upward due to buoyancy and stored in the tank which can be used directly.
A collector essentially consists of the following components:
1) A coated flat plate which absorbs solar radiation
Figure 1. Solar irradiation map (Source: SWERA, UNEP/ GEF).
and transforms it into thermal energy 2) An insulated storage tank used to reduce thermal losses of heated water glass or plastic 3) Cover to reduce upward thermal losses of the collector 4) Bottom insulation to reduce downward thermal losses 5) Tubes and channels for circulating water to collect thermal energy 6) Wooden or metallic frame to house the collector assembly Solar water heater is basically a flat-plate [9] collector in which heat transfer fluid is water. In Figure 2, the working principle of solar water heater has been shown.
5. Data Analysis
The reading collection of the room & tap water temperature of 100 Liter and 200 Liter solar water heater was started from November 1, 2008. As Thursday and Friday are the weekly holidays at BUET, no data could be taken at those days. Data has been collected up-to October 31, 2009. So a full cycle data of complete one year has been collected successively.
There was some drop in temperature as the pipes were
Figure 2. Thermosyphone principle of solar water heater (Source: LGED).
long between water heater tank and the tap in the wash basin. Moreover, 200 Liter pipes are not insulated. Although 100 Liter heater piping was insulated but rats and birds destroyed it in two weeks after installation. So there is also loss of temperature in 200 Liter heater. A solution could be to paint the piping with black color. The temperature retaining capability of 200 liter heater is better (Figure 3 & Figure 4) than 100 liter heater.
Temperature variation in the curve is due to foggy days during winter months in November and December. The comfortable temperature during winter month for household purpose is about 32˚C - 4˚C, which can easily be attained.
6. Conclusions
It is found from the data that the solar water heaters are working without disturbance. The tap water temperature is about 25˚C to 30˚C higher than room temperature during day time. It is expected that during evening hours it should be around 20˚C higher than room temperature. This hot tap water when mixed with cold tap water can be used comfortable according to comfort level of the user. Data for one year has been collected to analyze fully the
Figure 3. Solar water heater performance (morning).
Figure 4. Solar water heater performance (afternoon).
performance of the solar water heaters over the whole year.
7. Acknowledgements
The authors would like to thank the Centere for Energy Studies, Bangladesh University of Engineering & Technology (BUET) for technical and data support.