Isolation of Iron Bacteria from Washing Sludge Filters Kolda (Senegal) Water Treatment Station and Study of the Kinetics of Biological Degradation of the Iron (II) ()
1. Introduction
Iron is one of the most abundant metals in the earth’s crust and is generally associated with manganese [1]. Dissolved iron concentrations in anaerobic groundwater may exceed levels of the order of 10 mg∙L−1, but the usual iron concentrations are between 0.02 and 10 mg∙L−1 [2]. When exposed to oxygen, the iron can form insoluble products, mainly in the form FeCO3, Fe(OH)2 or Fe(OH)3. Iron oxides are highly insoluble products with a brownish color [3]. This can lead to undesirable color problems in groundwater for drinking water [4]. Therefore, the excessive presence of iron in drinking water and organisms such as the World Health Organization (WHO), the European Commission, USEPA (United States), and Canada should be avoided Health and Welfare Canada has established a maximum level of iron contamination of 0.3 mg∙L−1 [5]. The removal of dissolved iron (FeII) from groundwater is generally achieved by oxidation, precipitation and sand filtration for the separation of oxidized insoluble products [1]. The chemical oxidation of iron dissolved by oxygen can be described by the following general equation [6]
This expression implies that a homogeneous oxidation of iron can be accompanied by a heterogeneous auto-catalytic action, in the presence of the existing Fe solid phase [1]. However, heterogeneous auto-catalytic oxidation is more important than the homogeneity of the oxidation processes, in drinking water treatment units. Iron can be removed by aeration and precipitation or by the use of oxidants [7]. It is for these reasons that chemical oxidation is generally required to achieve iron precipitation within reasonable time and at pH values common to water practice, i.e. between 6 and 8. It is well established that KMnO4 and ClO2 are effective oxidants for dissolving iron in a wide range of variable pH values [8]. However, in water treatment processes, the use of chemical reagents should be minimized, not only because of the increased operational costs of applied treatment methods, but also because of the secondary impacts that may result from formation of residues and by-products [8].
For these reasons, the biological oxidation of iron has been considered as a viable alternative to groundwater treatment. However, there is little information to date, probably because the problem of iron contamination is less frequent and also because the process involved is considered more complex than in the case of the biological oxidation of iron [9]. The biological oxidation of FeII is generally carried out by microorganisms [10]. In particular, the oxidation of iron can be carried out by species belonging to several types such as Leptothrix, Crenothrix, Siderocapsa Gallionella, etc. [10]. The bacteria responsible for this process seem to be bacteria without risk to the environment. These bacteria are able, thanks to the enzymes and biopolymers they develop, to oxidize iron biologically by catalyzing the oxidation of the divalent metal by dissolved oxygen, even in low concentrations, and by fixing it on their cell membranes, their sheaths, their peduncles. The precipitates formed are then strongly adherent to bacterial polymers.
In the present study, the biological oxidation of iron by bacteria isolated on a petri dish was studied during the treatment of iron-doped water using test tubes. The kinetics of the bacterial oxidation of iron were examined and the results were compared with the respective kinetics of the oxidation of bacterial iron as well as with the values obtained in the literature concerning abiotic oxidation. So far, most work related to bacterial oxidation of iron has been focused on batch investigations or under natural conditions [11], while detailed information on the products of biological oxidation of iron has not been reported for the case. Ongoing treatment of groundwater, but only for groundwater treatment plants in situ [12].
The main objective of this study is to study the biological degradation capacity of the iron present in our sample by isolated microorganisms and to determine the kinetic model that describes our experimental results. These results obtained will make it possible to calculate the effectiveness of this biological elimination:
2. Materials and Methods
2.1. Presentation of the Sludge Sampling Area
The Kolda region is located 484 km from the capital of Senegal (Dakar region) by The Gambia. It lies between 12˚20 and 1˚40 north latitude and 13˚ and 16˚ west longitude. It covers an area of 13,721 km2 or 7% of the national territory. It is limited to the North by the Gambia, to the East by the Tambacounda region, to the west by the Sedhiou region and to the South by Guinea Bissau and Guinea Conakry [13]. In addition, rainwater feeds the surface water of Continental Terminal, Miocene (50 and 150 m depth) and Quaternary. The Maestrichtian can be reached within 160 m in the south center and south-east of the region [14]. The quality of the water is good, nevertheless with contents of heavy metals including iron which exceed 10 times the norms of potability. Sampling was carried out at the de-ironing station installed in the city.
2.2. Sampling Methodology
Our choice is justified by the fact that the groundwater of this zone is quite loaded with iron and manganese. The sludge was collected at the Kolda water treatment plant. This sludge comes to us precisely from the filtration bed of the ironing unit. The sludge was put in plastic bags. These were kept cool in a cooler at about 4˚C (Figure 1).
2.3. Methodologies and Materials Used for Dosages
The sludge was extracted at the bottom of the filters. Samples were taken using a sterile spatula at a depth of 40 cm. For each sample, 100 g of sludge taken are put in sterile plastic bags. Mud samples are kept cool (4˚C). For seeding and isolation, we use Petri dishes (Figure 2) containing nutrient agar (GN).
In order to be in the calibration range, [Fe2+]0 < 6 mg∙L−1, we prepared a stock solution of 4 × 10−5 M iron sulfate (FeSO4) dissolved in distilled water. In 100 ml
Figure 1. (a) Kolda (Senegal) Station; (b) bed iron filtration; (c) washing sludge.
Figure 2. (a) Isolation of bacteria on petri dishes; (b) Test tube: contact between water doped with Fe (II) and bacteria.
volumetric flasks numbered from 1 to 7, put the volumes of reagents indicated in the following table, and adjust to the mark (Table 1). After adjusting to volume, mix thoroughly and let sit for 5 to 10 minutes. In the meantime, prepare the reference and then measure the optical density at 510 nm from the reference solution.
3. Results and Discussion
The calibration curve is then obtained from the measurement of the absorbance of each standard solution (Figure 3).
The concentration of the sample taken is calculated by multiplying by 10 the concentration obtained (to take into account the dilution factor). The corresponding iron concentration is calculated from the following relation:
3.1. Effect of Initial Iron Concentration as a Function of pH
The influence of the initial iron concentration in the synthetic solution on the performance of the biological elimination of iron by microorganisms was studied for different initial iron concentrations of 1, 2, 3, 4 and 5 mg∙L−1. The tests were carried out at different pH (pH = 3.4 - 3.6; pH = 7.3 - 7.5 and pH = 9.8 - 10), an operating pressure of 1.013 bar and a temperature of 2˚C ± 1˚C.
Figure 3. Calibration curve of the absorbance of the solution as a function of concentration.
Table 1. Preparation of solutions for the calibration curve.
Figure 4 and Figure 5 show the influence of the initial concentration of iron as a function of time (day) for different pH of the solution. Figure 4 shows that for an initial concentration of 5 mg∙L−1, an instantaneous increase in iron concentration, up to 5.4 mg∙L−1, is observed after three (3) days of incubation for pH = 3.4 - 3.6 and pH = 7.3 - 7.5 solutions. We observe, then a gradual decrease to 4.83 mg∙L−1 and 4.69 mg∙L−1 after 10 days incubation respectively for pH = 3.4 - 3.6 solutions and pH = 7.3 - 7.5. On the other hand, pH = 9.8 - 10 we recorded an instantaneous decrease after the first days of incubation up to 4.65 mg∙L−1 after 10 days.
Furthermore, Figure 5 shows that for an initial concentration of 4 mg∙L−1, an instantaneous increase in iron concentration is observed from the first day of incubation for the different solutions. We then observe a decrease in the concentration in the three tubes to reach 3.56 mg∙L−1, 3.43 mg∙L−1 and 3.32 mg∙L−1 after 10 days of incubation respectively for the solutions of pH = 3.4 - 3.6, pH = 7.3 - 7.5 and pH = 9.8 - 10. Indeed, in view of the results obtained the biological elimination of iron is more effective in the tubes with an initial concentration of 4 mg∙L−1. Because the ratio C/C0 passes from 0.94 to 0.85 respectively for initial
Figure 4. Kinetics of iron oxidation by microorganisms and evolution of iron concentration ([Fe2+]0 = 5 mg∙L−1, Patm = 1.013 bar and T = 21˚C ± 1˚C).
Figure 5. Kinetics of iron oxidation by microorganisms and evolution of iron concentration ([Fe2+]0 = 4 mg∙L−1, Patm = 1.013 bar and T = 21˚C ± 1˚C).
concentrations of 5 to 4 mg∙L−1 for the same pH = 7.3 - 7.5. Under the same conditions, however, for a pH = 3.4 - 3.6, the C/C0 value increases from 0.96 to 0.89 and for a pH = 9.8 - 10, the ratio increases from 0.93 to 0.83. This trend is observed, with treatment rates becoming more effective for lower and lower initial concentrations and basic pH. Therefore, the kinetics of iron removal is slow and inefficient for initial concentrations of iron ≥ 5 mg∙L−1 and acidic pH. It should, therefore, be at basic pH to remove iron in the case of our study. This hypothesis could be considered for the treatment of drinking water, but it would require an increase in the costs related to the exploitation and a difficulty to manage the adjustment of the pH of the water except if the water is not very buffered. These microorganisms are then able to degrade the surplus of iron in the groundwater.
In order to confirm the hypothesis that the efficiency of biological treatment increases with lower iron concentrations, we also studied the influence of the initial iron concentration as a function of time (day) for different pH of the solution for initial iron concentrations of 1, 2 and 3 mg∙L−1 materialized in Figures 6-8 below. In addition, it has been established by several authors that at high pH
Figure 6. Kinetics of iron oxidation by microorganisms and evolution of iron concentration ([Fe2+]0 = 3 mg∙L−1, Patm = 1.013 bar and T = 21˚C ± 1˚C).
Figure 7. Kinetics of iron oxidation by microorganisms and evolution of iron concentration ([Fe2+]0 = 2 mg∙L−1, Patm = 1.013 bar and T = 21˚C ± 1˚C).
Figure 8. Kinetics of iron oxidation by microorganisms and evolution of iron concentration ([Fe2+]0 = 1 mg∙L−1, Patm = 1.013 bar and T = 21˚C ± 1˚C).
(higher than the values studied), the kinetics of biological oxidation of ferrous iron increases [15] [16] [17]. On the other hand, at high concentrations, the formation of ferric hydroxide is more pronounced (high turbidity of the solution); which should, therefore, increase the kinetics of the oxidation reaction by the bacteria. But, we have noted at this level lower percentages of degradation. These experimental data confirm the work of some authors, that for high values of initial ferrous iron concentration, i.e. concentrations above 5 mg∙L−1, the microorganisms could become ineffective.
Figure 6 shows that for an initial concentration of 3 mg∙L−1, an instantaneous decrease in iron concentration, from the first day of incubation for the three (3) solutions of pH = 3.4 - 3.6, pH = 7.3 - 7.5 and pH = 9.8 - 10. For this initial iron concentration, we recorded C/C0 values of 0.84, 0.76 and 0.71 respectively for solutions of pH = 3.4 - 3.6, pH = 7.3 - 7.5 and pH = 9.8 - 10. With regard to Figure 7 for an initial concentration of 2 mg∙L−1, we observe the same trends as in Figure 6. Indeed, an instantaneous decrease in iron concentration is noted, from the first day of incubation for the three (3) solutions of pH = 3.4 - 3.6, pH = 7.3 - 7.5 and pH = 9.8 - 10. In addition, we recorded C/C0 values of 0.70, 0.62 and 0.52 respectively for solutions of pH = 3.4 - 3.6, pH = 7.3 - 7.5 and pH = 9.8 - 10. This evolution of the kinetics of biological degradation of iron (Figure 8) is manifested in the same way for an initial concentration of 1 mg∙L−1. Moreover, we recorded higher C/C0 ration values compared to higher concentrations. As a result, biological treatment becomes more effective at low initial iron concentrations and basic pH (pH is one of the important parameters that changes filtration performance). Thus, which could relate to low concentrations, the formation of ferric hydroxide is more pronounced; which subsequently increases the kinetics of the oxidation reaction.
3.2. Linear Regression Analysis of the Biological Elimination of FeII
Experiments performed by adding FeII to the distilled water stream, at different initial iron concentrations described above, were expressed as log ([Fe (II)]t/[Fe (II)]0) as a function of time (contact time with the empty bed) (Figures 9-13).
Figure 9. Linear regression analysis of the biological elimination of Fe (II) versus treatment time for an initial Fe (II) concentration of 5 mg∙L−1.
Figure 10. Linear regression analysis of the biological elimination of Fe (II) versus treatment time for an initial Fe (II) concentration of 4 mg∙L−1.
Figure 11. Linear regression analysis of the biological elimination of Fe (II) versus treatment time for an initial Fe (II) concentration of 3 mg∙L−1.
Figure 12. Linear regression analysis of the biological elimination of Fe (II) versus treatment time for an initial Fe (II) concentration of 2 mg∙L−1.
Figure 13. Linear regression analysis of the biological elimination of Fe (II) versus treatment time for an initial Fe (II) concentration of 1 mg∙L−1.
The linearity of the curves revealed that iron oxidation also followed a first-order kinetic rate, given by the following equation:
For a pH and initial concentration of variable iron, the kinetic constants found by applying the kinetic model above to our experimental results are equal:
• Solution 1: C0 = 5 mg∙L−1 (k = 0.0203 mn−1 for a pH = 3.4 - 3.6; k = 0,0205 mn−1 for a pH = 7.3 - 7.5 and k = 0.0101 mn−1 for a pH = 9.8 - 10);
• Solution 2: C0 = 4 mg∙L−1 (k = 0.036 mn−1 for a pH = 3.4 - 3.6; k = 0.0651 mn−1 for a pH = 7.3 - 7.5 and k = 0.0297 mn−1 pH = 9.8 - 10);
• Solution 3: C0 = 3 mg∙L−1 (k = 0.0234 mn−1 for a pH = 3.4 - 3.6; k = 0.0099 mn−1 for a pH = 7.3 - 7.5 and k = 0.0272 mn−1 for a pH = 9.8 - 10);
• Solution 4: C0 = 2 mg∙L−1 (k = 0.051 mn−1 for a pH = 3.4 - 3.6; k = 0.0605 mn−1 for a pH = 7.3 - 7.5 et k = 0.0662 mn−1 pH = 9.8 - 10);
• Solution 5: C0 = 1 mg∙L−1 (k = 0.0949 mn−1 for a pH = 3.4 - 3.6; k = 0.1055 mn−1 for a pH = 7.3 - 7.5 and k = 0.1238 mn−1 for a pH = 9.8 - 10).
These results clearly show that the biological oxidation of iron is a very slow reaction under the specified experimental conditions of synthetic waters doped with iron. In fact, we observed higher kinetic constant values at C0 = 1 mg∙L−1 (k = 0.0949 mn−1 for a pH = 3.4 - 3.6, k = 0.1055 mn−1 for a pH = 7.3 - 7.5 and k = 0.1238 min−1 pH = 9.8 - 10). Therefore, it is under these conditions that the reaction of biological degradation of iron (II) by ferrobacteria is faster compared to others. Then this result confirms the conclusion that was emitted during the tests of the study of the kinetics of iron oxidation by microorganisms at different pH and concentrations (the biological treatment of iron becomes more efficient for initial iron concentrations low and basic pH). This can also be indicated by the calculated half-life constant of the biological oxidation of iron, which was found to be 9 days at C0 = 1 mg∙L−1 and pH = 9.8 - 10. This is the smallest half-life time from all experiments of different experimental conditions.
In many works, to increase iron degradation yields the authors coupled the biological oxidation of iron to that of the physic-chemical (Pourbaix diagram). This was found in studies of [18]. The comparison between the removal of FeII biological and physic-chemical in a similar processing unit showed that the removal of iron by the chemically accounted for almost 50% of the total iron removal. However, these values are consistent with the work of [19] concerning the biological iron removal of groundwater.
3.3. Percentage Evaluation of Biological Treatment
The results of this experiment are used to calculate the percentage of iron removed by the bacteria. The kinetics achieved previously used to calculate the percentage of iron removed after 10 days of contact time (incubation) with the isolated microorganisms in Petri dishes. Table 2 contains all the biological treatment rates.
Looking at the percentage values of eliminated iron obtained during the kinetic tests, it should be noted that we recorded low iron abatement rates for high initial concentrations, especially at relatively acidic pH. The results (Table 2) show that the elimination percentages of the most efficient iron are obtained in the tube 5 - C = 1 mg∙L−1 (Tube 5a - pH 3.4 - 3.6 - FeII = 37.211%; Tube 5b - pH = 7.3 - 7.5 -% FeII = 52.592, Tube 5c - pH = 9.8 - 10 -% FeII = 59.453). In conclusion, the iron contents vary according to the pH of the culture medium, these results are significant but more need to be optimized because the remaining iron contents (after 10 days of incubation) are well above the norm WHO recommendation in drinking water.
Table 2. Percent removal of iron from microorganism-doped water after 10 days of contact time (incubation).
Overall the view of our results, the decrease in iron content could be explained by the fact that certain bacteria (iron bacteria) develop the ability to use iron (III) as electron acceptor under anaerobic conditions. There is, therefore, oxidation of iron (II) by the microorganisms and later by the oxygen thus causing the formation of precipitate in the form of iron (III). Bacteria yet are able to interact indirectly with the iron through the production of metabolites. Some bacteria use iron (II) as an electron donor. Microbiologists have discovered that some bacteria are able to capture and immobilize iron. The bacteria responsible for this process seem to be bacteria without risk to the environment. These bacteria are able, thanks to the enzymes and biopolymers they develop, to oxidize iron biologically by catalyzing the oxidation of the divalent metal by dissolved oxygen, even in low concentrations, and by fixing it on their cell membranes, their sheaths, their peduncles, etc. The precipitates formed are then highly adherent to bacterial polymers. Increasing the iron content observed in some tubes could be explained by two things:
• First, this increase in iron concentration over time could be due to cell death leading to reduction in the number of bacteria able to capture iron, in addition, it would release iron in the medium;
• Also, he might have contamination at our manipulations thus inhibiting the activity of iron bacteria (iron bacteria) or during the operation of determining iron by ortho-phenanthroline method.
4. Conclusions
In this paper, the results of the study of the kinetics of biological iron removal of reconstituted synthetic waters and the evaluation of removal rates from biological oxidation were examined. Biological iron removal was found to follow a first-order reaction rate. Reaction rates are quite slow, but nevertheless the treatment process is quite economical and environmentally friendly because the additional use of chemical reagents is not necessary during the treatment period.
The study showed that the performance in terms of efficiency depends strongly on the initial concentration of iron. Indeed, we recorded higher abatement rates for low concentrations (Table 2). Regarding the influence of operating conditions including pH, it also shows a very significant effect on the iron removal rate. In other words, optimal efficiency is obtained at pH = 9.8 to 10 basic and C0 = 1 mg∙L−1. The results obtained are promising in terms of elimination rates from biological oxidation to comply with WHO recommendations.